atoautomation-blog
atoautomation-blog
ATO Automation
17 posts
Don't wanna be here? Send us removal request.
atoautomation-blog · 7 years ago
Video
youtube
How to measure vibration with ATO vibration meter?
0 notes
atoautomation-blog · 7 years ago
Video
youtube
Safety Light Curtain Relay/PLC Control Wiring
https://www.ato.com/safety-light-curtain
ATO safety light curtain adopts light curtain and controller separate design. The light curtain can be used with the controller, and also can be directly connected to the safety relays and PLC to achieve automatic stop function in dangerous situation. In this video, ATO will show you how to connect type 4 safety light curtain with relays/PLC (include a 24V DC switching power supply and a stack light).
0 notes
atoautomation-blog · 7 years ago
Video
youtube
How to test a voltage regulator?
A voltage regulator is a device used to automatically regulate voltage level. If you want to know whether there is a big error in the output voltage specification of the regulator you purchased, in this video ATO.com https://www.ato.com/ will show you how to test a single phase 220V, output 0~330V AC voltage regulator with multimeter.
0 notes
atoautomation-blog · 7 years ago
Video
youtube
Testing step up & step down 220V to 110V isolation transformer
https://www.ato.com/isolation-transformers
ATO.com provides you high performance single phase and three phase dry type isolation transformers which designed to step up/ down the voltage as per requirements and widely used in various power supply sites with frequency 50Hz or 60Hz and voltage less than 1000V AC. Need more detail of ATO isolation transformer? Here is a good explanation about it in this video. To test the accuracy of the transformer voltage, we take a 3000 VA single phase 220V iuput to 110V output isolation transformer as an example.
0 notes
atoautomation-blog · 7 years ago
Text
Why should use a VFD?
1 - Reduce Energy Consumption and Energy Costs
If you have an application that does not need to be run at full speed, then you can cut down energy costs by controlling the motor with a variable frequency drive, which is one of the benefits of Variable Frequency Drives.
2 - Increase Production through Strict Process Control
By operating your motors at the most efficient speed for your application, fewer mistakes will occur, and thus, production levels will increase, which earns your company higher revenues. On conveyors and belts you eliminate jerks on start-up allowing high through put.
Find a VFD for your application now. 1 hp to 100 hp Variable Frequency Drive on ATO.com have Single Phase Output VFD, Single Phase to Three Phase VFD and Three Phase VFD can be choose.
0 notes
atoautomation-blog · 7 years ago
Video
youtube
Testing Automatic Voltage Stabilizer (140V to 270V AC)
https://www.ato.com/3-kva-automatic-voltage-stabilizer
A voltage stabilizer is a device that automatically adjusts the output voltage to stabilize it. In this video ATO uses a voltage regulator and multimeter to test the output voltage of the 3 kva voltage stabilizer which has 140V to 270V AC input, 220V AC output. After testing, we may see that the output voltage is within 220V ± 6%, which is in line with the standard.
0 notes
atoautomation-blog · 7 years ago
Video
youtube
https://www.ato.com/power-inverters
Power Inverters are widely used to charge devices by converting DC power to AC power. In this video, ATO takes a 1000 watt pure sine wave power inverter (24V DC to 220V AC) as example, and test its input & output side with multimeter. To test further, ATO uses it to run a fan and charge a cell phone, and both works well.
0 notes
atoautomation-blog · 7 years ago
Video
youtube
Run a 3-phase motor on single phase power supply by VFD
https://www.ato.com/single-phase-to-three-phase-vfd
If you have a three phase motor but only single phase power supply. Using ATO single phase to three phase VFD can operate the three phase motor. ATO single phase to 3 phase variable frequency drives convert the single phase into a three phase, allowing the use of more efficient and less expensive three phase motors. Now you can start by following our video.
0 notes
atoautomation-blog · 7 years ago
Video
youtube
PLC control Nema 23 external linear autuator stepper motor system https://www.ato.com/stepper-motor-linear-actuators ATO external stepper linear actuator in this video is 2 phase 4 wire comes in Nema 23 frame size. We will show you how to use PLC connect to the hybrid stepper motor system, and control this external stepper motor linear actuator for simple forward and reverse motion by the pulse and direction command issued by PLC.
0 notes
atoautomation-blog · 7 years ago
Video
youtube
How to use a handheld infrared thermometer? https://www.ato.com/handheld-non-contact-digital-infrared-thermometer/ The ATO handheld non-contact infrared thermometer provides accurate surface temperature scan with backlight LCD display, easy to read, compact size and light weight. This video shows basic usages of handheld infrared thermometer and tells how easy and interesting to use the infrared thermometer.
0 notes
atoautomation-blog · 7 years ago
Video
youtube
How to test 24V DC solenoid valve with a multimeter? 
https://www.ato.com/solenoid-valve-2-way-normally-closed-12v-24v-220v-for-air-water-oil
A solenoid valve is a basic automation component to control the fluid. In this video, ATO shows how 24V DC water solenoid valve is operating internally, and then uses a multimeter to test the solenoid voltage when the power is on or off.
0 notes
atoautomation-blog · 7 years ago
Video
youtube
How to program a digital up/down counter for beginners? https://www.ato.com/digital-counter-6-digit-up-down ATO digital counter is a 6 digit digital up/down counter with small size and high speed. In this video, ATO will show you how to connect digital up/down counter to a photoelectric sensor or a rotary encoder, and how to set the basic parameters of digital counter. Finally, there's a counting test for digital counter with photoelectric sensor.
0 notes
atoautomation-blog · 7 years ago
Video
youtube
https://www.ato.com/digital-panel-meter In this video, ATO will show you: How to use a digital panel meter? How to connect a digital panel meter and a displacement sensor to form a simple displacement measuring system? How to set the basic parameters of digital panel meter?
0 notes
atoautomation-blog · 7 years ago
Video
youtube
https://www.ato.com/brushless-dc-motors This video shows you how to connect a 50W 24V 3 phase BLDC motor to its driver and achieve speed control.
0 notes
atoautomation-blog · 7 years ago
Video
youtube
https://www.ato.com/three-phase-induc... The 3-phase induction motor on ATO.com can be connected in delta (△) connection and star (Y) connection. This video shows ATO changes the induction motor wiring from star connection to delta connection. To demonstrate this change clearly, the induction motor is also connected to ATO 1-phase in 3-phase out VFD and it runs normally under the control of VFD.
0 notes
atoautomation-blog · 7 years ago
Link
https://www.ato.com/single-phase-vfd The operations of using VFD for single phase motor speed control are not complex. In this video, ATO will show you details about running a single phase motor on a VFD. It's important to note that there are two wiring methods for single phase motor connecting to ATO single phase VFD: wiring of removing motor capacitor & wiring of keeping motor capacitor. At first, you should choose the wiring method you needed, and then set basic parameters step by step.
0 notes
atoautomation-blog · 7 years ago
Text
ATO 1 kVA to 100 kVA Isolation Transformers
Isolation transformers from ATO.com with different power capacity, 1 kVA to 100 kVA, increase and decrease alternating currents. They can be built to scale and generally handle any amount of voltage necessary, depending on how many times the coils are wound. Isolation transformers reduce electrical and electromagnetic interruptions from other power sources and devices and improve signal strength in radio and wireless communication systems.
1 note · View note