Shamrocks Plumbing and Heating - Kelowna's favorite plumbing contractor
Don't wanna be here? Send us removal request.
Text
Plumbers Kelowna - Shamrocks Plumbing and Heating
When selecting a plumbing contractor, you need more than basic repairs, you need engineering-grade solutions that meet local codes and optimize system performance. Shamrocks Plumbing and Heating applies rigorous technical standards to every residential and commercial project in Kelowna, ensuring reliability, energy efficiency, and code compliance.
youtube
System Design & Piping Specifications
Our plumbers Kelowna size and configure water distribution systems according to peak demand, static pressure, and flow requirements:
Municipal feed: ¾″ to 1″ copper or PE pipe, 50–80 psi static pressure, ~9 gpm flow
Piping materials: Type L copper (ASTM B88), PEX-A (CSA B137.5), CPVC (ASTM D2846)
Expansion control: ASME-rated expansion tanks selected per thermal expansion coefficient
Pressure drops, velocity (0.6–0.9 m/s for supply lines), and fixture units (per IPC) dictate pipe diameters to minimize noise and maintain balanced flow.

Precision Leak Detection & Pressure Testing
We employ advanced diagnostics to locate and verify system integrity:
Acoustic correlators and ground microphones for sub-slab leaks
Air–water pressure testing at 1.5× design pressure to check joints and valves
Infrared thermography and tracer-gas (nitrogen–helium mix) scanning for hidden breaches
Detected anomalies trigger sectioned isolation, targeted repair, and retesting to guarantee zero leakage before finishing.
Fixture Installation & Flow Control
Installing high-performance plumbing fixtures involves calibrated flow control and backflow prevention:
Thermostatic mixing valves (ASSE 1017) set to ±1 °C tolerance, 1.5–2.2 gpm output
Ceramic-disc cartridge faucets with ¼-turn actuation and integrated PRV (1.5 gpm max)
Backflow assemblies (double-check or reduced-pressure zones) per CSA B64 specifications
Each fixture is flow-tested with a digital flowmeter and certified by our plumbers Kelowna to maintain water quality and prevent cross-connections.
Hot Water Systems: Storage & Tankless
We design hot-water delivery around user profiles, space constraints, and energy targets:
Parameter Storage Tank Heaters Tankless Water Heaters Capacity 40–100 gal (151–378 L) glass-lined Modulating burner 30–199 kBTU/h
Recovery Rate 35–55 gph at ΔT 90 °F 4–9 gpm at ΔT 35 °F Efficiency 0.60–0.67 EF 0.82–0.95 UEF
Control Fixed thermostat, T&P valve 150 psi PID-controlled modulating valve
Maintenance Anode rod inspection every 3 years Descale cycle at 6–12 months
We select models with high Uniform Energy Factor (UEF) and integrate ECM circulation pumps for zone-based delivery.
Hydronic Heating & Distribution
Our heating solutions balance thermal comfort with system longevity:
Furnaces: 60–150 kBTU/h input, AFUE 95% modulating burners, ECM blower
Condensing boilers: 80–199 kBTU/h input, 90–98% thermal efficiency, stainless-steel heat exchangers
In-floor radiant: ⅜″ PEX tubing at 150 mm centers, ΔT 20 °C, max 1.5 bar, insulated manifolds with flow meters
Controls include outdoor-reset thermostats, zone valves, and pump curves matched to head losses for precise temperature regulation.
Drain Cleaning & Sewer Rehabilitation
Clogs aren’t just inconvenient, they jeopardize system hygiene and structural integrity:
Hydro-jetting: 2,000–4,000 psi at 8–15 gpm, nozzle selection per pipe diameter
Mechanical augers: 12 mm–25 mm cable, 1 HP motor, 300 rpm, max 50 m reach
Trenchless repair: CIPP liners (host pipe diameters 100–300 mm), slip-lining, pipe bursting
CCTV camera inspections provide pan/tilt/zoom diagnostics to pinpoint tree root ingress, corrosion, or misaligned joints.
Preventative Maintenance Programs
Regular servicing extends equipment life and prevents costly failures:
Annual plumbing tune-up: joint torque checks, service valves exercise, PRV calibration
Heating system inspection: heat-exchanger hydro-flush, combustion analysis, flue-gas CO/O₂ measurement
Sump pumps: dual-float switch test, ⅓ HP motor check, backup battery system diagnostics
Customized maintenance schedules align with manufacturer recommendations and local water hardness profiles.
24/7 Emergency Response & Field Protocol
When time is critical, our emergency task force mobilizes:
Rapid dispatch with full diagnostic toolkits
On-site triage: isolate zones, drain down, stabilize system
Permanent repair or engineered temporary bypass
Post-repair pressure testing and certification
Our goal is to restore service within one hour of arrival, minimizing water damage and downtime.
For engineered plumbing and heating solutions in Kelowna that adhere to the highest technical standards, contact Shamrocks Plumbing and Heating today. Whether it’s a precision installation, system audit, or emergency intervention, our technicians deliver performance, safety, and peace of mind.
Give us a call or request a technical consultation online, your engineered comfort solution awaits.
Shamrocks Plumbing & Heating 1325 Elwyn Rd, Kelowna, BC V1X 5M9 (250) 300-9948 shamrocksplumbingandheating.ca