#CompactClean
Explore tagged Tumblr posts
homekitdecor · 4 days ago
Text
Tumblr media
If you’re dealing with a small kitchen, the Magic Bullet 7-Piece Blender Set is your best bet. It’s powerful, affordable, and fits anywhere. You can make smoothies, salsa, baby food—whatever you need—without taking up precious counter space.
0 notes
ottsterom · 9 months ago
Text
Stash This Lightweight Vacuum in Your Glove Compartment #CompactCleaning #CarEssentials #GadgetLover
0 notes
smarthomegadgets17 · 1 year ago
Video
youtube
Dirt Devil Broom Vac Cordless | Dirt Devil Broom | Dirt Devil Vacuum | D...
0 notes
fadingtimetravelqueen · 2 years ago
Text
Wireless Handheld Vacuum Cleaner
https://rb.gy/2wgcg
Tumblr media Tumblr media Tumblr media
1 note · View note
hudsonespie · 4 years ago
Text
DESMI Launches Two New BWMS Expanding Coverage for Ships at Sea
To meet market and customer demand, DESMI has developed two new Ballast Water Management Systems (BWMS) covering bulker solutions and ships sailing in or primarily in IMO waters. The new systems are CompactClean Bulker and CompactClean OptIMO. These new systems join the DESMI portfolio of BWMS alongside the well-known CompactClean BWMS.
“Not all ships are engaged in global trade but rather in regional or domestic trade, and as such a significant part of the world’s fleet will never, or only rarely, enter US waters. Such vessels can benefit from a BWMS solution that is optimized to IMO requirements and not US Coast Guard requirements, and this is exactly what we have developed with our new CompactClean OptIMO BWMS,” says Rasmus Folsø, CEO DESMI Ocean Guard. “The OptIMO BWMS meets the USCG requirements and can be operated in a US compliance mode, which involves a smaller maximum flowrate, but does make it suitable for operation in US waters when needed.”
The new CompactClean OptIMO BWMS has lower power consumption and fewer UV lamps and thus provides both CAPEX and OPEX savings, as well as an even smaller footprint than the market leading footprint of CompactClean BWMS. 
With the CompactClean OptIMO BWMS, DESMI provides the customers with an opportunity to select a BWMS that is carefully optimized to the needs of the vessel and its operation. If max flowrate treatment is required globally, including US waters, then the market leading CompactClean BWMS, the only UV system available that does not employ special flow reduction when operated in US compliance mode, is the right choice. 
If there is no need to operate the BWMS at max flowrate in US compliance mode, either because US waters are never entered or because the vessel’s operation profile allows the discharge of ballast water at a reduced flowrate when in US waters, then OptIMO is the right choice as it provides both CAPEX and OPEX savings.
The CompactClean Bulker – is a BWMS optimized for the operation of Bulk Carriers or other vessel types, where the discharge of ballast water is performed at increased flowrate. With the Bulker solution, DESMI can tailor-make a BWMS for customers which will allow one flowrate during ballast, and another and higher flowrate during de-ballast. As the filter is only applied during ballast operation it can be downsized to match the lower flow during ballast. Therefore, CompactClean Bulker grants the customer a CAPEX reduction, as well as OPEX reduction in case the filter internals need replacement during the life of the BWMS.
A quick view of all three system types is available at www.desmioceanguard.com  
from Storage Containers https://www.maritime-executive.com/article/desmi-launches-two-new-bwms-expanding-coverage-for-ships-at-sea via http://www.rssmix.com/
0 notes
filtration-products · 7 years ago
Text
DESMI system receives IMO type approval
DESMI’s CompactClean Ballast Water Management System has received IMO type approval.
Danish pump manufacturer and water management specialist, DESMI, has announced that its CompactClean Ballast Water Management System (BWMS) has received IMO type approval according to the revised IMO BWMS code, known as the revised G8.
This means that the CompactClean BWMS becomes one of only two systems worldwide approved for installation on vessels also after 28 October 2020, when all BWMS installed on ships on must be approved according to the revised BWMS code.  
IMO type approval is the first step in the planned approval process for the CompactClean BWMS, which will now continue with the submission of a full application for US Coast Guard (USCG) type approval and also for ATEX and IECEx requirements for installation in hazardous zones on e.g. oil and chemical tankers, expected before the end of 2018.
The CompactClean system comes in 14 different flowrate sizes, with the smallest having a maximum flowrate of 35 m3/h, and the largest having a maximum flowrate of 3000 m3/h.  It consists of an automatic backflushing filter, a UV unit, valves, sensors, and controls.  The system also includes features such as automatic generation of PDF reports that document all the performed ballast water treatment operations, in a format that is suitable for submission to local port authorities.
    About Filtration Products: Filtration Products site posts the recently released announcements, summaries and separation break thoughs straight from the separation venues. Filtration-Products keeps you savvy on filtration and all the major technical items including spun depth filtration, pleated filter elements, melt blown filters, bag filtration, RO filtration, from brands such as Culligan made for water treatment, and anything else the separation market has to report on.
from Filtration Products https://ift.tt/2NAK9JY
0 notes
homekitdecor · 4 days ago
Text
Tumblr media
If you’re dealing with a small kitchen, the Magic Bullet 7-Piece Blender Set is your best bet. It’s powerful, affordable, and fits anywhere. You can make smoothies, salsa, baby food—whatever you need—without taking up precious counter space.
0 notes
homekitdecor · 4 days ago
Text
Tumblr media
Tired of messy blender cleanups? Here’s how to clean your Magic Bullet Blender in 60 seconds:
Add warm water and a drop of dish soap. Run the blender for 5 seconds. Rinse and let it dry. Done. No hassle, no leftover smells.
0 notes
homekitdecor · 4 days ago
Text
Why I Can’t Live Without My Magic Bullet I used to skip breakfast because I didn’t have time. Then I found the Magic Bullet Portable Blender MBPB50100—game changer. It's compact, lightweight, and blends everything from frozen fruit to veggies in seconds. Perfect for students, busy moms, or anyone always on the go
0 notes
hudsonespie · 5 years ago
Text
Six Questions About Ballast Water Management Answered
This white paper provides an overview of the two most prominent ballast water management (BWMS) technologies installed on today’s vessels-ultraviolet (UV)-based systems and electrochlorination (EC) systems. It offers a comparison between the two technologies and explores the benefits and challenges faced by their operators. In particular, this white paper puts a spotlight on the overlooked but potentially serious complications related to operating UV BWMS with different operating modes to obtain respectively USCG or IMO compliance.
As of October 2019, close to 10,000 vessels— nearly 10 percent of the global vessel fleet—have been fitted with a ballast water management (BWM) system. According to Clarkson’s World Fleet Register, the most common technologies for BWM are ultraviolet (UV)-based systems and electrochlorination (EC) systems. Figure 1 shows the different technologies installed on vessels.
Having a full understanding of the different BWM technologies, their benefits and limitations, sets the foundation for making the right decision when selecting a BWM system. Specifically, it’s important to understand how the BWM system impacts a vessel’s operations, as the ballast water being pumped on board the vessel can vary considerably, and different BWM systems handle the various water qualities differently.
Treating ballast water
The treatment of ballast water before discharge is important because it prevents the transport and introduction of potentially invasive species in local eco-systems through ship’s ballast water. Therefore, it is one of the approaches ship owners and operators typically adopt in order to be in compliance with the mandatory discharge standards imposed by the International Maritime Organization (IMO) and the U.S. Coast Guard (USCG).
Navigating the BWM convention
The Ballast Water Management (BWM) Convention administered by IMO sets the international standard for ballast water treatment.
The IMO guidelines for type approval of BWM systems were revised in October 2018. Since the revision, the IMO now states that type approval according to the new BWM system code MEPC.300(72) (also referred to as the revised G8) is mandatory for all BWM systems installed on vessels after October 28, 2020.
CompactClean, a BWM system from DESMI, is type approved in accordance with the IMO’s BWM system code and as such ready for the future.
UV based treatment BWM systems based on UV treatment typically apply two treatment steps: filtration and UV treatment. During ballasting operations, both filtration and UV treatment are applied. After filtration, the ballast water is routed via UV chamber(s) to the ballast tanks. To avoid potential non-compliant ballast water discharge due to organism regrowth in the tanks, the ballast water is treated with UV light again during de-ballasting. The water bypasses the filter and gets pumped through the UV chamber before it is discharged (see Figure 2).
Understanding UV
The UV treatment uses either low pressure or medium pressure UV lamps to break down cell membranes and/or damage their DNA, which respectively kills the organisms or destroys their ability to reproduce, making them non-viable. The percentage of non-viable or killed organisms in the water after treatment depends on the applied UV dose.
What is UV dose?
The UV dose depends on the UV intensity (UV-I) and exposure time, and is simply defined as the product of these two parameters. UV-I measures how much light (or energy) reaches a given measurement point.
Most UV systems measure the UV-I, but the systems can vary considerably in terms of the UV lamp being used and the sensor setup. In particular, the distance between the sensor and the UV lamp influences the measured UV-I. For this reason, UV-I values shouldn’t be used to compare systems.
Fortunately, another measurement called UV-transmission (UV-T) can be used to compare systems. A more reliable UV performance measure, UV-T measures the capability of UV light to penetrate water. When the UV-T is high, that is, close to 100 percent, the water is very clear. This means the UV light can penetrate deep into the water. When the UV-T is low, the water is not very clear, and the UV light can only penetrate the water for a limited distance.
This means that the lower the UV-T a BWM system can treat and still meet the IMO and USCG discharge standards, the better the performance of the system. CompactClean can treat ballast water and effectively kill organisms down to 42 percent UV-T, which means even extremely challenging water can be treated to meet both IMO and USCG discharge standards.
USCG versus IMO
A known challenge for UV-based BWM systems is the different regulations and efficacy testing methods adopted by two regulatory bodies, the U.S. Coast Guard and the IMO.
The USCG evaluates BWM system performance using a test which measures the number of living organisms after treatment (FDA/CMFDA method). On the other hand, the IMO evaluates UV-based BWM systems by determining whether the treated organisms are viable or non-viable, i.e. whether they capable of reproducing. If they cannot reproduce, IMO determines that the organisms do not pose a threat of becoming invasive species. The organisms’ ability to reproduce is measured with the MPN (most probable number) method.
It is a fact that a significant larger UV-dose, approximately two to three times higher, is required to kill organisms rather than rendering them non-viable. 
Switching between codes and modes .
This disparity between the USCG and IMO testing methods implies that many UV systems increase UV dose levels when treating ballast water to be discharged in U.S..-regulated waters. This is typically achieved by reducing the water flow by 50 percent or more while using maximum power settings. Therefore, these systems have two different operating modes that the operator must choose between before starting a ballast operation: U.S. and IMO. The U.S. mode is essentially an operation mode with max power settings combined with reduced flow.
Numerous complications exist for ship operators using a BWM system that must switch operation modes between U.S.- and IMO-regulated waters. Already during ballast uptake operation, careful attention needs to be paid to whether the ballast water will be discharged in U.S.- or IMO-regulated waters. This determines which operation mode of the system must be selected. The consequence is that the operator of the system needs to know where the ballast water that is taking on board is going to be discharged. If the vessel is taking on ballast water in e.g. Shanghai, but knows that it will be discharged in the U.S., the U.S. operation mode must be selected, even though the vessel is in China, far from U.S. regulated waters.
Naturally, the selection of either IMO or U.S. mode becomes quite complicated if the operator does not know where the ballast water he is taking on board is going to be discharged. It will be tempting to choose the IMO mode, because U.S. mode will typically mean reduced flow, which leads to longer ballast operation and hence longer port stay. However, if the IMO mode is used during ballast operation, but then later on it is determined that the ballast water shall be discharged in the U.S., the ballast water will be non-compliant and must be treated as such. This means the local port state authorities in the U.S. must be contacted and an agreement about what to do must be reached. This could be a requirement that the vessel must conduct a full ballast water exchange at least 200 nautical miles from shore in water at least 200 meters in depth.
A similar situation will occur if the ship’s next port of call is changed from a non-U.S. port to a U.S. port: All the ballast water on board treated in the IMO mode will then be non-compliant.The CompactClean does not need a special mode to comply with USCG requirements, but has just one global approved mode for worldwide operations.
The advantage of using a single operation mode globally is that it removes the need to know the de-ballast location at the time of ballast uptake. This means the ship can never get into a situation where the ballast water on board is compliant for discharge in one location, but not in another.
Hold times take time
The USCG requires UV systems to have a minimum hold time, which is defined as the shortest allowable time between ballast water uptake and ballast water discharge. If the minimum required hold time is not achieved before a de-ballast operation, it could result in serious operational issues such as e.g. inability to start cargo operations because ballast water cannot be discharged yet.
To complicate matters further, hold time requirements are for many BWM systems dependent on UV-I and salinities (for example fresh, brackish or sea water). The required hold time can also be affected when UV-I drops suddenly during ballast water uptake. This makes operation and planning even more complicated, as the required hold time is not known until the ballast operation has been completed. For some systems, a hold time of up to 72 hours in USCG-regulated waters should be observed.
In U.S.-regulated waters the CompactClean only requires a holding time of two hours for all salinities irrespective of UV-I levels. In IMO waters the CompactClean has no hold time requirement. This makes planning easy, and ensures operational flexibility.
Power consumption: is it a big deal?
Power consumption is often an important consideration when selecting BWM equipment. Yet, while power consumption makes up a proportion of a ship’s operational expenditures (OPEX) over time, BWM systems are only operated a few percent of the time in a year. So when comparing BWM systems, the difference in annual OPEX is actually insignificant.
The following case example illustrates this point. Consider a bulk carrier with a total ballast pump capacity of 1,000 m3/h with following operating profile. The total ballasting and de-ballasting operating hours per year is 768 hours. If the vessel is operating only in IMO-regulated waters, the total fuel oil consumption per year for one CompactClean-1000 system (assuming an average power consumption of 86 kW) is 14.8 tons.
In comparison, a system with a slightly lower average power consumption (e.g., 60 kW) consumes 10.3 tons of fuel oil per year. From a cost perspective, if the price of fuel oil is 390 EUR per ton, the total fuel cost for operating the CompactClean-1000 system for one year is approximately 5,800.00 EUR, while the 60 kW system would cost 4,100.00 EUR, i.e. a difference of 1,700.00 EUR.
It should be noted that this case example does not consider holding time or flowrate restrictions in U.S. mode, and as illustrated below the small fuel saving that can be obtained in IMO mode with a lower power consuming system is quickly converted into an additional cost when the same system occasionally has to be operated in its USCG mode.
CompactClean does not apply flow reduction to meet USCG discharge standards. But other, slightly lower power-consuming BWM systems as the one in this example, typically apply a 50 percent reduction in flowrate when ballasting and de-ballasting in U.S. mode. In this example, it means the time required for ballasting and de-ballasting in one year would increase from 768 hours to 1,536 hours. This increases the total fuel cost from approximately 4,100.00 EUR to 8,200.00 EUR, which is 2.400 EUR higher OPEX in a year than with the CompactClean.
Assuming the maximum power draw of a BWM system is available on the ship during cargo operation, it is hard to argue that a BWM system with low power consumption should be prioritized without carefully examining the system’s limitations. This is especially true in terms of hold time, flow restrictions and operating system complexity, which can easily create much more cost than the small saving obtained due to slightly lower power consumption.
Stripping ballast tanks
When it comes to stripping ballast tanks, there are many different solutions available on the market. These solutions vary in how ballast water is treated during the stripping process. Here is an overview of the different solutions.
Solution 1: Treated ballast water is reserved in one ballast tank and used as drive water for the ejector. The drive water is then combined with the stripped water from the tank to be re-treated using UV treatment.
Solution 2: The ejector setup is connected to a holding tank and water from this is used as drive water and recirculated while stripping the ballast tanks. When the holding tank reaches a certain level, it can be emptied by de-ballasting through the BWM system. If the holding tank setup is utilised, the holding tank should never be emptied completely to ensure the drive pump can take suction. 
Solution 3: Ambient sea water is pumped through the ejector as drive water. Pre-treated ballast water stripped by the ejector is combined with the ambient sea water and the combined stream is pumped through the UV chamber for treatment. Another version of this solution is to filter the ambient sea water. Prefiltering the ambient sea water removes debris and sediments, reducing the risk of damaging the UV-based system or other BWM system components.
Our solution
CompactClean comes with an integrated stripping solution in the form of a backflush pump that can also be used as a stripping pump.
The DESMI Modular S pump creates enough vacuum to evacuate all air from an empty suction pipe and lift the water 7 metres up to the pump, making it ideal as a stripping pump. It is also fitted with a frequency drive that automatically stops the stripping operation after the pump has sucked air, resulting in a smoothly automated stripping operation.
The benefits of this solution include a reduction in power consumption compared with the ejector solution, no need for a dedicated stripping ejector and minimal wear and tear on the UV unit as only filtered ballast water is guided through the UV chamber.
Now that the UV-based systems have been explored in detail, let’s have a closer look at the other most commonly installed BWM system on vessels—electrochlorination.
Electrochlorination systems offer cost-effective solutions on high ballast-flow vessels (i.e., flows above 1500 m3/h) with limited power availability. Electrochlorination describes the generation of hypochlorite from saltwater electrolysis. It can be divided into two main types: in-line (Figure 4), and side-stream (Figure 5).
Both types of electrochlorination typically combine mechanical filtration with treatment with chlorine, which is produced by an electrolysis unit. For side-stream technologies, approximately 1–2 percent of total ballast water flows to the electrochlorination unit and is re-injected to the ballast water flow.
Food for thought
When compared with UV-based treatment systems, electrochlorination systems are considered more complex and require more components to be installed. Therefore, making the decision to install an electrochlorination system requires some considerations.
During electrochlorination, by-products like hydrogen gas, for example, are generated. Depending on the BWM system technology, hydrogen gas can be separated from the side-stream, diluted with air using small fans and ventilated out of the ship. This is important because hydrogen gas poses an explosion risk, and unfortunately there are a few examples of electrochlorination BWM systems causing explosions onboard vessels.
Chlorine, which is widely used as a disinfectant, is highly toxic and corrosive in nature, which means it poses a hazardous risk to the crew and a long-term risk to ballast water tank coatings. When determining the efficiency of electrochlorination systems, the salinity and temperature of the ballast water being treated should be considered. This is because the efficiency of the electrolysis unit when generating the disinfectants depends on these water quality parameters. Generally, when salinity and temperature levels are low, additional voltage is required to generate the disinfectants, resulting in higher power consumption.
On the subject of salinity
The electrochlorination systems work well for vessels operating in warmer, high-saline waters where sufficiently dissolved salts are available. However, for vessels operating in fresh or low-salinity brackish waters, particularly in colder climates, electrochlorination technologies present some challenges.
To compensate for the low salinity problems, vessels operating in these conditions might carry marine water or salt brine so that the electrochlorination systems work properly.
Using sea water or salt brine from the aft peak tank (APT) to compensate for low salinity of the ballast water can cause some problems. If the APT is continuously de-ballasted to feed the side-stream electrolytic cells during cargo operations, trim control on the vessel while conducting cargo operations could be compromised.
Furthermore, reserving tanks for high-saline water displaces cargo capacity, which in turn means lost income and makes some charter guarantees difficult to meet.
Chemical considerations
Before ballast water is discharged, chemical agents such as sodium thiosulfate, sodium bisulfite or sodium metabisulfite are prepared and injected to neutralize the remaining chlorine based active substances, measured as Treatment Residual Oxidants (TRO). This treatment is mandatory to avoid unauthorised excessive TRO discharges. The maximum allowable discharge of TRO concentration is 0.1 mg/L.
Time to weigh up the costs
Electrochlorination systems generally consume less power than UV-based treatment systems. However, taking both power consumption and TRO-neutralising chemicals into account, the OPEX of electrochlorination systems often exceed that of UV systems.
Consider a tanker fitted with an electrochlorination system. The power consumption of the system is 2.9 kW per 100 m3 and the salinity is above 30 PSU (Practical Salinity Unit). The figures in Table 2 indicate a yearly cost of neutralization chemicals of 8,900.00 EUR.
The figures in Table 3 indicate a yearly cost of power consumption of 1,400.00 EUR, resulting in a combined cost of 10,300.00 EUR, without including costs for spare parts, cleaning chemicals, or heating requirements when operating in colder climates.
Treating the same amount of ballast water (i.e., 552,000 m3) with a CompactClean-1000 system costs approximately 8,300.00 EUR in fuel oil, whereas the minimum power consumption corresponds to a total fuel of cost of just 3,100.00 EUR.
The OPEX alone is worth considering and clearly indicates that UV-based systems are highly competitive when selecting a BWM technology. Keep in mind that the figures used in these examples are based on favourable water temperature and salinity conditions of electrochlorination systems. The power consumption will increase considerably in cold and low salinity waters. 
Automated neutralization
Neutralization of ballast water is usually conducted by an automatic dosing of a neutralization agent and TRO analysers. The TRO analysers measures the amount of TRO, and based on this the amount of required neutralization chemicals is determined.
However, these analysers are known to be delicate and often cause problems due to malfunctions. TRO analysers require regular maintenance and chemical refills (e.g., pH buffers and DPD chemicals). The DPD chemicals have limited shelf-life and need to be changed at least semi-annually (even if not used), and often expire prematurely due to on board conditions. Cleaning of the TRO analysers every few months to avoid corrosion is required as well.
Clogging issues abound
Since sea water is used as an electrolyte in electrochlorination systems, hard scale deposits accumulate on the surfaces of electrochlorination cells, which causes unwanted clogging.
To prevent clogging, regular cleaning of electrolysers is necessary. This may require additional cleaning chemicals and maintenance for the BWM system. Furthermore, electrolytic cell replacements are costly. 
Filter clogging halts operations
A common issue with BWM systems is filter clogging because it stops the ballast operation altogether. This interferes with the vessel’s operations causing costly down-time for ship owners and operators. It is an issue often experienced by vessels operating in muddy waters.
Filters tend to clog due to their design, with the usual culprit being the backflush mechanism. There is speculation that mesh size also plays a role in clogging, but as long as the backflush mechanism is properly designed and matched to the mesh size, it will effectively remove filtrate from the filter, and the mesh size does not matter.
Tackling muddy waters
During the design phase of CompactClean, a filter that can tolerate and perform well in muddy waters was chosen. The filter’s backflush cleaning device ensures efficiency by effectively flushing the entire filter mesh area in 30 seconds. Additionally, the CompactClean system includes a backflush pump that minimizes restrictions and pressure loss issues in the filter backflush discharge line.
The CompactClean was tested in the muddy waters of the Yangtze River in China with impressive results. Even under the worst conditions the filter managed to handle full flowrate without being close to clogging up or even entering continuous backflushing.
Summary
In general filtration + UV-treatment is a very simple and well known technology, and with no by-products produced. UV-treatment BWM systems are considered CAPEX competitive for flowrates up to 1,000 – 1,500 m3/h. Their performance is not affected by water salinity or temperature, but is dependent on the UV-transmission of the ballast water.
It is to be noted that UV BWM systems require treatment both during uptake and discharge, and under U.S. regulations they are subject to minimum hold time restrictions.
While EC-based systems are considered competitive when it comes to capital expenditures (CAPEX) for flowrates above 1,000–1,500 m3/h, their installation and complexity should be considered. The potentially dangerous nature of chlorine and hydrogen gas, both present in EC-based systems, requires additional risk, health and safety measures.
In addition, the limitations of EC-based systems in terms of water temperature and salinity should be examined carefully and compared to the operational needs of the ship. Finally, the operator must ensure availability of neutralization as well as cleaning chemicals.
Making the right choice
Selecting a BWM system entails much more than just selecting technology and equipment. Finding the right supplier is extremely important as long-term service and support is crucial to keeping the BWM system operational throughout a vessel’s lifetime and compliant in both USCG- and IMO-regulated waters. Continued support, including service and after-sales, is important for ship owners and operators. Adding to the support is extensive training for BWM system operators, so that they can be confident in their ability to handle any given situation.
DESMI - more than an equipment supplier
At DESMI we know that selecting and installing a ballast water treatment system is about much more than equipment supply and requires planning well in advance. Throughout the selection process DESMI delivers deep knowledge and we understand that not all type of technologies, systems etc. with their limitations and specifications will work acceptably on all vessels.
In addition, DESMI offers on-board inspection and engineering support for the installation. The projects are followed closely by one of our project managers who understand the entire process and what it takes for a successful installation and commissioning.
Ballast water treatment systems are generally standardized equipment. It is however important to choose a supplier that has the capability as well as flexibility to assist if the installation somehow requires customization apart from the standardized equipment. At DESMI we are ready to provide customized solutions - e.g. valve controls or customized interfaces - to ensure successful projects.
Last but not least, DESMI is a trustworthy partner with more than 185 years of history and a supplier of a range of equipment to the marine and other markets. You can therefore count on DESMI being by your side for many years to come.
This post is sponsored by DESMI. 
from Storage Containers https://maritime-executive.com/article/six-questions-about-ballast-water-management-answered via http://www.rssmix.com/
0 notes
hudsonespie · 6 years ago
Text
DESMI Ocean Guard’s CompactClean BWMS Receives USCG Type Approval
DESMI Ocean Guard A/S is pleased to announce that its CompactClean Ballast Water Management System (BWMS) has received US Coast Guard Type Approval. This approval comes just a few months after the CompactClean BWMS received IMO type approval and means that the system is now approved for worldwide operation.
Image Credits: desmi.com
On April 16, 2019 DESMI Ocean Guard’s CompactClean Ballast Water Management System (BWMS) received US Coast Guard (USCG) Type Approval. The approval is valid for all salinities and seawater temperatures and has no requirement for a special operating mode in US Territory. Furthermore, the CompactClean BWMS has recently been approved according to ATEX and IECEx requirements for installation in hazardous zones on e.g. oil and chemical tankers, and this is also expected to be added to both IMO and USCG Type Approval certificates soon.
“With the so far unmatched versatility of the CompactClean BWMS, enabling installation on board any ship type and allowing for treatment of all kinds of ballast water anywhere in the world, the CompactClean BWMS is leading the way. Add to this the smallest footprint in the industry, simplicity, user friendliness, ease of installation and credible long term global support and service from a company with close to two centuries of history, and you have the explanation why CompactClean is being selected by more and more” explains Rasmus Folsø, CEO of DESMI Ocean Guard. He continues: “Some of the World’s largest and leading shipowners have found the CompactClean BWMS the superior solution, and selected it for their entire fleet. We are grateful for their trust in our product and our company, and we are happy to see that as systems are installed and put into operation on more and more vessels, we receive positive feedback from involved shipowners.”
The CompactClean BWMS comes in 14 different flowrate sizes, with the smallest having a maximum flowrate of 35 m3/h, and the largest having a maximum flowrate of 3000 m3/h.
As a closing remark Rasmus Folsø adds: “In addition to the CompactClean BWMS, DESMI Ocean Guard also provides the market’s most energy-efficient IMO approved BWMS. This system, called RayClean, can in some cases still be the optimal solution if available electrical power is a limiting factor and available space is less of an issue.”
Press Release
Report an Error
from Storage Containers https://www.marineinsight.com/shipping-news/desmi-ocean-guards-compactclean-bwms-receives-uscg-type-approval/ via http://www.rssmix.com/
0 notes
hudsonespie · 7 years ago
Text
CompactClean Ballast Water Management System’s Landbased Type Approval Tests Successfully Completed
DESMI announced that all the required landbased testing of the CompactClean Ballast Water Management System has been successfully completed. The testing was performed in accordance with both IMO and US Coast Guard requirements and paves the way for issue of both IMO and USCG type approval certificates later this year.
DESMI Ocean Guard’s CompactClean Ballast Water Management System (BWMS) has now successfully completed all the landbased testing required by both IMO and US Coast Guard (USCG). The testing includes a total of 15 landbased tests, 5 in each of the 3 salinities required: fresh water, brackish water, and marine water.
Image Credits: desmi.com
Results of the testing confirm that the system meets the stringent discharge requirements without any special operating mode to be employed in US territory and without any minimum holding time to be observed between ballast water uptake and discharge.
“We are especially pleased that no less than 7 landbased tests performed in different salinities and at various levels of UV-transmission of the water have been successfully completed with the shortest holding time allowed for landbased testing. This means that there is no required minimum holding time for the CompactClean system. Requirement for minimum holding times for type approved BWMSs is one of the main issues that ship operators are facing within ballast water treatment today, and we are happy to be able to provide a solution with our CompactClean system,” explains Rasmus Folsø, CEO of DESMI Ocean Guard A/S, and continues:
“It is a significant achievement that the CompactClean system does not need a special US operation mode to meet the USCG requirements in US territory. With just one operation mode used globally, there is no need for knowing the de-ballast location at the time of ballast uptake, in order to determine if the BWMS should be operated in IMO or US mode. Likewise, there are no issues related to mixing IMO and USCG treated ballast water when water is treated in one mode during ballast operation, but then pumped to a tank with remains of water treated in another mode. Mixing of ballast water treated in different modes is also a concern when water is moved internally from tank to tank during a voyage to compensate for consumed fuel. All these issues represent serious complications to the ship operator when using BWMS that must be switched to one operation mode in US and another in the rest of the world. With CompactClean we have managed to solve this.”
The CompactClean BWMS consists of an automatic backflushing filter, a UV unit, valves, sensors, and controls. The UV unit has a unique and patent pending shape that is the result of hundreds of state of the art numerical simulations. This shape ensures optimum dosage of the UV to all organisms in the water, and the result is a system that meets even the very strict USCG type approval requirements. Furthermore, the system includes many features that are of importance to the daily operation. One example is automatic generation of PDF reports that document all the performed ballast water treatment, in a format that is suitable for submission to local port authorities and others. Another example is that the system includes a pump that can be used as stripping pump under ballast stripping operations, thus solving one of the main problems for ballast water management system installations today.
Image Credits: desmi.com
The CompactClean BWMS is currently undergoing type approval testing according to both IMO and USCG requirements, under the surveillance of Lloyd’s Register. All landbased tests have been completed and the final shipboard test and the environmental tests are planned to be completed in May 2018, paving the way for issue of IMO and USCG type approval certificates around June/July 2018.
Press Release: desmi.com
Report an Error