deebbielabtron
deebbielabtron
Untitled
56 posts
Don't wanna be here? Send us removal request.
deebbielabtron · 1 year ago
Text
External Dimension (W × D × H)=760-times-670-times-1100-mm; Internal Dimension (W × D × H)=600-times-600-times-600-mm; UV Lamp=30-w-times-1; HEPA Filter=efficiency-ge-99-999-at-0-3-micro-m-h13-filter; Clean Air Speed=0-36-to-0-54-m-s; Shop online at Labtron.cc.
Tumblr media
0 notes
deebbielabtron · 1 year ago
Text
Type=portable-air-ionizer; Air filter=air-purification-composite-filter-with-primary-filter-activated-carbon-filter-photocatalyst-filter; Disinfection=air-dynamic; Circulating Air=ge-600-m-lt-sup-gt-3-lt-sup-gt-h; Temperature Range=0-to-39-ordm-c-screen-displays-10-to-35-ordm-c-temperature-range; Shop online at Labtron.cc.
Tumblr media
0 notes
deebbielabtron · 1 year ago
Text
Optical System=infinity -optical-system-lt-br-gt-with-bright-field-dark-field-dic-polarizing-units; Viewing Head=seidentopf-trinocular-head-inclined-at-30-deg-lt-br-gt-interpupillary-distance-48-to-75-mm; Reflected Illumination=24-v-100-w-halogen-light-lt-br-gt-brightness-adjustable-kohler-illumination-with-aspherical -condenser -lt-br-gt-polarizer-amp-analyzer-lt-br-gt-integrate-board-for-polarizer-amp-analyzer-lt-br-gt-blue-green-yellow-filter-ground-glass-filters; Transmitted Illumination=swing-out-condenser-n-a-0-9-0-25-lt-br-gt-24v-100-w-halogen-light-with-aspherical-condenser-lt-br-gt-blue-filter; Working Stage=maximum-sample-height-30-mm-lt-br-gt-double-layer-mechanical-stage-186-times-138-mm -lt-br-gt-moving-range-74-times-50-mm -lt-br-gt-includes-specimen-preparation-plate-slide-glass;Shop Online at Labtron.cc
Tumblr media
1 note · View note
deebbielabtron · 1 year ago
Text
Ultrasonic power=2-to-150-w-adjustable; Disruption capacity=0-1-to-150-ml; Standard probe/horn=phi-6-mm; Display=4-3-inch-tft-touch-screen; Input method=touch-control; Shop online at Labtron.cc.
Tumblr media
1 note · View note
deebbielabtron · 1 year ago
Text
Operating frequency=19-5-to-20-5-khz; power consumption=1200-w; horn=20-mm; total working time=1-to-999-mins; duty ratio=0-1-to-99-9; Shop online at Labtron.cc.
Tumblr media
0 notes
deebbielabtron · 1 year ago
Text
Measuring range=0-3-50000-mm-lt-sup-gt-2-lt-sup-gt-s; Measure position=2; Bath volume=25-l; Timing accuracy=0-01-s; Temperature range=5-deg-c-95-deg-c; Shop online at Labtron.cc.
Tumblr media
0 notes
deebbielabtron · 1 year ago
Text
"Maximum Wafer Diameter: 4 inches; Speed Adjustable Range: 100-to-9999 rpm-adjustable; Acceleration Range: 100-to-9999 rpm-s; Speed Resolution: 1 rpm; Max Single Step Time: 3000-s; Shop online at Labtron.cc!
Tumblr media
0 notes
deebbielabtron · 1 year ago
Text
Vacuum degree = 0-to-90 kpa; accuracy = 1 fs; resolution = 0-1 kpa; vacuum chamber effective size = 270 x 210 mm; vacuum chamber size = 300 x 350 mm; Shop online at Labtron.cc.
Tumblr media
0 notes
deebbielabtron · 1 year ago
Text
Sample (size) length=0-to-200-mm-adjustable; Sample width: 15 mm; measuring range: 0-to-30 n-tissue-paper-0-to-100-n-0-to-300-n-0-to-500-n-0-to-1000-n; Measurement mode=; Stability=; Shop online at Labtron.cc!
Tumblr media
0 notes
deebbielabtron · 1 year ago
Text
Injection rate: 0-to-4 g-min; air flow for sterilization: 2-4 ml/sup-gt-3-lt-sup-gt-min; Vaporization Temperature=le-100 °C; Humidity for Dehumidification=le-30 °R; Sterilizing Space=le-503; Shop online at Labtron.cc.
Tumblr media
0 notes
deebbielabtron · 1 year ago
Text
Specimen sectioning speed=0-to-1-3-mm-s-adjustable; Vibrating range=0-to-1-mm; Section thickness range=10-to-300-micro-m; Minimum setting value=1-micro-m; Specimen lifting platform range=20-mm;Shop Online at Labtron.cc
Tumblr media
0 notes
deebbielabtron · 1 year ago
Text
Capacity=10-l-2-64-gallons-lt-hr-gt-6000-g-13-2-lbs; Sample’s maximum aggregate size is 50 mm x 2 inches. Water inlet valve Hose=1-4-inches-id-inner-diameter; Vacuum hose and aspirator=3-8-inches-npt-fitting; Flange=10-3-4-inches-od-outer-diameter-273-mm; Shop online at Labtron.cc.
Tumblr media
1 note · View note
deebbielabtron · 1 year ago
Text
Ambient temperature=5°C to 35°C; relative humidity=le-85; buffer vessel volume=1000 mL; maximum residual pressure=le-2 mm-hg; Temperature-controlling accuracy=plusmn-1; Shop online at Labtron.cc.
Tumblr media
1 note · View note
deebbielabtron · 1 year ago
Text
Speed=adjustable; Speed Range=1000-to-2800 rpm; Operation mode=circling; Circling Diameter=4-4-mm; Permissible moisture=0-8; Shop online at Labtron.cc.
Tumblr media
1 note · View note
deebbielabtron · 1 year ago
Text
Measuring range=1-6-000-000-cp-100-40-000-000-cp-200-80-000-000-cp-800-320-000-000-cp; Rotating speed=0-1-200-rpm; Rotor=; Measuring Error (Newtonian liquid)=plusmn-1-0-full-range; Repeatability error (Newtonian liquid)=plusmn-0-5; Shop online at Labtron.cc!
Tumblr media
1 note · View note
deebbielabtron · 1 year ago
Text
Wavelength Range: 325-1000 nm; Setting: Wavelength: Automatic; Spectral Bandwidth: 2-nm; Wavelength Accuracy: Plus-1-0 nm; Wavelength Repeatability: Le-0-2-nm; Shop online at Labtron.cc.
Tumblr media
0 notes
deebbielabtron · 1 year ago
Text
"Operating temperature=ambient-temperature-to-300-deg-c; Heating rate=50-deg-c-h-5-plusmn-0-5-deg-c-6-min-120-deg-c-h-12-plusmn-1-deg-c-6-min; Maximum temp. error with heating speed=plusmn-5-deg-c-under-50-deg-c-h plusmn-1-deg-c-under-120-deg-c-h Range of deformation: 0-to-10 mm; Deformation measurement method: digi-gauge; Shop online at Labtron.cc.
Tumblr media
0 notes