Don't wanna be here? Send us removal request.
Text

Our curated range of energy products valves in particular, covers mechanical as well as electric Smart Valve options from the world’s most credible Smart Valve suppliers FlowCon and Belimo. Energy control valve (smart control valve) applications
Coil optimisation based on flow rate and temperature differential
Remote setting and monitoring of smart control valves
Water quality monitoring
The FlowCon Energy FIT System includes: A FlowCon SM PICV (1/2? – 2?, threaded), (65-250mm, flanged)
FIT.1 = 1/2" – 1" PN25 (0.176-0.685 l/s)
FIT.2 = 1" – 2" PN25 (0.513-2.34 l/s)
FIT.3 = 65-80mm PN40 (1.48-9.89 l/s)
FIT.4 = 80-10mm PN40 (3.49-20.2 l/s)
FIT.5 = 125-150mm PN40 (6.48-29.5 l/s)
FIT.6 = 200-250mm PN40 (9.21-76.8 l/s)
0 notes
Text

The past 10 years FloControl have supplied the most compact pre-assembled FCU PICV Valve Set to mount directly onto fan coil units from any manufacturer. We are able to offer PICV Valve Arrangements with a variety of system connections and features including strainers, automatic air vents, flushing valves and drain, fully compliant with BRSRIA BG29/21. The PICV Valve Arrangement includes the innovative 3 in 1 FlowCon PICV and actuator, designed to use full stroke control with 41 maximum flow rate settings per valve type, altogether covering flow rates from 0.00482 – 0.736 l/s, suitable for heating and cooling applications [-20°C to +120°C].
Product Features
Flushing By-Pass assembly on 40mm centres to fit over extended drip tray.
Vertically or horizontally configured.
Blank cap for flushing through the assembly.
PT Plug & Combined PT Plug & Drain on PICV to aide system balancing.
Removable PICV Insert for flushing and easy replacement.
FCU connections included as standard.
A wide selection of system and flexible hose connections available.
Union connections at all joints for easy valve alignment and removal.
Strainer, Flow Measurement, Union Drain valves off the shelf.
Wide range of Electric and Thermal Actuators.
Labelled, cross-referenced to the schedule, terminal unit and location in the building.
0 notes
Photo

The Smart Energy Valve maintains correct flow despite pressure changes and guarantees that flow change and change in actuator position only occur when demand requirements change or ?T is outside specification.
The FlowCon Energy FIT System includes: A FlowCon SM PICV (1/2? – 2?, threaded), (65-250mm, flanged) • FIT.1 = 1/2? – 1? PN25 (0.176-0.685 l/s) • FIT.2 = 1? – 2? PN25 (0.513-2.34 l/s) • FIT.3 = 65-80mm PN40 (1.48-9.89 l/s) • FIT.4 = 80-10mm PN40 (3.49-20.2 l/s) • FIT.5 = 125-150mm PN40 (6.48-29.5 l/s) • FIT.6 = 200-250mm PN40 (9.21-76.8 l/s)
0 notes
Photo
FloControl offers the most comprehensive range of Double Regulating Valves, also known as Variable Orifice Double Regulating Valve or DRV Valve, to introduce a pre-set system resistance whilst offering the opportunity to isolate and return to the pre-set position. Traditional Globe Valve style Double Regulating Valves threaded from ½” – 2” and flanged 50mm – 600mm. Butterfly Valve style 65mm – 600mm Double Regulating Valve for applications with space limitations and cost effectiveness. WRAS-approved PN25 Variable Orifice Double Regulating Valve • Design in accordance to BS 7350 • Temperature range: -10°C to 130°C • Bronze Construction • ABS Hand-wheel operated • Numerical indicator • Characterised regulating disk • Supplied with two blank plugs as standard • Sizes: 1/2” – 2” with threaded end connections
0 notes
Photo

The 1/2" or 3/4" PICV Valve Arrangement is widely used on Fan Coil Units. The larger-size threaded or flanged PICV Valve Arrangement is well-suited for Zone, AHU, branch connection and Plantroom applications. Are you looking for a one stop shop for your fit out? Enquire about our Valve Package, which includes all PICV Valves, General and Public Health Valves as specified on your drawing. Smart Energy Valves are the ideal solution for efficient coil operation, monitoring and remote control. Energy valves measure the energy use, monitor coil performance and adjust the PICV Valve to deliver the design flow and temperature differential.
Product Information: A FlowCon SM PICV (1/2? – 2?, threaded), (65-250mm, flanged) • FIT.1 = 1/2? – 1? PN25 (0.176-0.685 l/s) • FIT.2 = 1? – 2? PN25 (0.513-2.34 l/s) • FIT.3 = 65-80mm PN40 (1.48-9.89 l/s) • FIT.4 = 80-10mm PN40 (3.49-20.2 l/s) • FIT.5 = 125-150mm PN40 (6.48-29.5 l/s) • FIT.6 = 200-250mm PN40 (9.21-76.8 l/s) A FlowCon (display) actuator (with or without failsafe function) A sensor kit including 2 temperature sensors and 2 pressure sensors The FlowCon Intelligent Interface
0 notes
Photo
Know all about how commissioning ultra-low pressure independent control valves (PICVs) in HVAC systems reduce energy costs and allow significant energy savings.
0 notes
Photo

While energy savings can be achieved, DeltaT control ONLY may compromise the occupant comfort. Therefore, energy products, a valve that is pressure AND temperature independent, were introduced in 2012 by Belimo (electronic) and in 2018 by FlowCon (mechanical). Connected and remotely controlled, these valves are also known as “smart valves” or “intelligent valves”. The most advanced smart valve even allows for glycol monitoring. Energy control valve (smart control valve) applications • Coil optimisation based on flow rate and temperature differential • Remote setting and monitoring of smart control valves • Water quality monitoring
0 notes
Photo

For over 10 years FloControl have supplied a full range of pre-assembled Fan Coil Unit Valve Sets to mount directly onto the FCU Unit from any manufacturer, including PICV, ABV 4-Port and Commissioning 4 Port Fan Coil Unit Valve Sets, fully compliant with BSRIA BG29/21. Whether it is a standard or highly customised FCU Valve Set, the FloControl FCU Valve Package Assembly is being supplied on the shortest lead time in the market. FloSet 4-Port comprises the FlowCon Flushing By-Pass on 40mm centres, 5 modes of operation including • Full isolation of the coil and high Kvs by-pass for full velocity system flush • FlowCon Flow Venturi Metering Station + 5% accuracy with integrated Test Point and fitted with Combined PT Plug & Drain in the Flow Branch and Optional Strainer (static pressure 20 Bar maximum) • Johnson Controls 4-Port Valve with 24V Electric Modulating or Raise Lower Actuator control • FlowCon E-Just or Composite Automatic Balancing Valve with an externally or internally adjustable, removable Insert, with an integrated Test Point & Combined PT Plug & Drain Valve in the Return Branch • Conex Compression FCU Connections for direct mounting onto the Fan Coil Unit over the extended drip tray • Female threaded system-side connections. Optional: Blank cap for flushing.
0 notes
Photo

FloControl is the exclusive distributor of the innovative FlowCon Pressure Independent Control Valve range, also known as PIC Valves or PICV Valves. FlowCon invented the PICV Valve and is the world’s largest specialised manufacturer of dynamic balancing and Pressure Independent Control Valves for the HVAC segment.
Product Information: A FlowCon Green PICV (1/2" – 2", threaded) A FlowCon (display) actuator (with or without failsafe function) A sensor kit including 2 temperature sensors and 2 pressure sensors The FlowCon Intelligent Interface Differential Pressure range: 16-800 kPaD 4 flowrate ranges from 0.0103 to 3.79 l/sec Pressure rating: PN25
0 notes
Photo

The Smart Energy Valve maintains correct flow despite pressure changes and guarantees that flow change and change in actuator position only occur when demand requirements change or ?T is outside specification. Readings of ?T, ?P, flow rate, energy and flow at valve location through Bluetooth FlowCon App or analogue to BMS. The smart energy valve solution is compact, allows for 360° installation with no piping restrictions. The energy valves are well suited for plant room and district heating applications, new builds or retro fit.
The FlowCon Energy FIT System includes: A FlowCon SM PICV (1/2? – 2?, threaded), (65-250mm, flanged) • FIT.1 = 1/2? – 1? PN25 (0.176-0.685 l/s) • FIT.2 = 1? – 2? PN25 (0.513-2.34 l/s) • FIT.3 = 65-80mm PN40 (1.48-9.89 l/s) • FIT.4 = 80-10mm PN40 (3.49-20.2 l/s) • FIT.5 = 125-150mm PN40 (6.48-29.5 l/s) • FIT.6 = 200-250mm PN40 (9.21-76.8 l/s)
0 notes
Photo

Whether it is a standard or highly customised FCU Valve Set, the FloControl FCU Valve Package Assembly is being supplied on the shortest lead time in the market. The Compact PICV and ABV-4 Port Fan Coil Valve Package is easy to select and is supplied pre-assembled, tested, set and ready to fit. Fan Coil Hook Up, Flypass and Miniflush are examples of manufacturer names for the Fan Coil Valve Package or refer to some of the functionality of the Valve Arrangement, e.g. Flushing Bypass Arrangement. he First Fit Kit comprises a 2 Union By-Pass on 80mm centres and a venturi metering station in the return branch, 2 system fittings and 2 blank caps. Strainer optional in the flow branch. The FCU Kit comprises a Green PICV fitted with a combined P/T Plug & Drain and FNP.0.2 actuator in the return branch and a combined P/T Plug & Drain in the flow branch.
Product Specifications - • Heating & Cooling Duty 0°C – +120°C • Static pressure 25 Bar maximum (strainer assemblies 20 Bar) • Differential pressure up to 800 kPa depending upon PICV insert selection • Pressure Independent Automatic Balancing and Control • Adjustable control characteristic (linear or equal percentage) • Actuator 360° mountable • Drain & Test Points in the flow and return • Flow rates 0.005 – 0.736 l/s, 41 settings per insert type (5 types in total) for superior accuracy • Line sizes DN15-20 • Fully tested, labelled, cross-referenced to schedule, with QR code link to technical data
0 notes
Photo

Designed for terminal units that service larger areas within a building such as Air Handling Units or CRAC Units, the AHU Valve Package supports higher flow rates. The AHU Valve Package incorporates any of the threaded larger-size PICV Valves up to 2? diameter, typically Green.2 or Green.3, a 2-Union flushing bypass, strainer & drain and can be mounted directly on the terminal unit, on 80mm or 105mm centres. Each AHU Valve Package is tested, labelled and set, ready to fit.
Product Information: • Pressure Independent Automatic Balancing and Control • Direct mounting for larger size terminal units • Self-calibrating full stroke IP54-rated Electric Modulating or Raise Lower Actuator • Venturi metering station for accurate flow measurement at the terminal unit • Strainer at the terminal unit with integral ball valve for easy basket removal • Back flush and drain at the terminal unit • Heating & Cooling Duty -15°C – +115°C • Static pressure 25 Bar • Differential pressure up to 800 kPa depending upon PICV selection • Linear or equal percentage control characteristic • Actuator 360° mountable • Flow rates 0.240 – 3.79 l/s, 41 settings for superior accuracy • Line sizes DN25-50
0 notes
Photo

Smart Energy Valves are the ideal solution for efficient coil operation, monitoring and remote control. Energy valves measure the energy use, monitor coil performance and adjust the PICV Valve to deliver the design flow and temperature differential.
The FlowCon Energy FIT System includes: A FlowCon SM PICV (1/2? – 2?, threaded), (65-250mm, flanged) • FIT.1 = 1/2? – 1? PN25 (0.176-0.685 l/s) • FIT.2 = 1? – 2? PN25 (0.513-2.34 l/s) • FIT.3 = 65-80mm PN40 (1.48-9.89 l/s) • FIT.4 = 80-10mm PN40 (3.49-20.2 l/s) • FIT.5 = 125-150mm PN40 (6.48-29.5 l/s) • FIT.6 = 200-250mm PN40 (9.21-76.8 l/s)
0 notes
Photo

For over 10 years FloControl have supplied a full range of pre-assembled Fan Coil Unit Valve Sets to mount directly onto the FCU Unit from any manufacturer, including PICV, ABV 4-Port and Commissioning 4 Port Fan Coil Unit Valve Sets, fully compliant with BSRIA BG29/21. Fan Coil Hook Up, Flypass and Miniflush are examples of manufacturer names for the Fan Coil Valve Package or refer to some of the functionality of the Valve Arrangement, e.g. Flushing Bypass Arrangement. • 6-Port diverting FCU Valve Set • Application: 1-Coil FCUs for combined heating and cooling duties
0 notes
Photo

FloControl offers the most comprehensive range of Double Regulating Valves, also known as Variable Orifice Double Regulating Valve or DRV Valve, to introduce a pre-set system resistance whilst offering the opportunity to isolate and return to the pre-set position. Traditional Globe Valve style Double Regulating Valves threaded from ½” – 2” and flanged 50mm – 600mm. Butterfly Valve style 65mm – 600mm Double Regulating Valve for applications with space limitations and cost effectiveness. Product Information: • WRAS-approved PN25 Variable Orifice Double Regulating Valve • Design in accordance to BS 7350 • Temperature range: -10°C to 130°C • Bronze Construction • ABS Hand-wheel operated • Numerical indicator • Characterised regulating disk • Supplied with two blank plugs as standard • Sizes: 1/2” – 2” with threaded end connections
0 notes
Photo
AHU Valves
Designed for terminal units that service larger areas within a building such as Air Handling Units or CRAC Units, the AHU Valves Package supports higher flow rates. The AHU Valve Package incorporates any of the threaded larger-size PICV Valves up to 2″ diameter, typically Green.2 or Green.3, a 2-Union flushing bypass, strainer & drain and can be mounted directly on the terminal unit, on 80mm or 105mm centres. Each AHU Valve Package is tested, labelled and set, ready to fit.
0 notes
Link
The AHU Valves Package incorporates any of the threaded larger-size PICV Valves up to 2″ diameter, typically Green.2 or Green.3, a 2-Union flushing bypass, strainer & drain and can be mounted directly on the terminal unit, on 80mm or 105mm centres. Each AHU Valve Package is tested, labelled and set, ready to fit.
0 notes