#twocompenent
Explore tagged Tumblr posts
z-man69 · 6 years ago
Text
Copy of Adhesive Technology: Ultrabond HS-1CC
Features & Advantages
ICC-ES ESR-4094 evaluation report for cracked and uncracked concrete
Code compliant in cartridge and bulk dispensing systems, IBC/IRC:  2018, 2015, 2012 & 2009
Florida Building Code (FBC) Compliant:  2017 & 2014
City of Los Angeles (LABC/LARC) Code Compliant:  2017
Abu Dhabi International Building Code (ADIBC) Compliant: 2013
ICC-ES AC308 and ACI 355.4 assessed for resisting short term loading conditions up to 205 °F (96 °C)
UL Certified – Drinking Water System Components to NSF/ANSI 61 & Lead Free to NSF/ANSI 372
Suitable for core drilled installations in dry or water saturated concrete
Multiple anchor types:  threaded rod, rebar & internally threaded inserts
OSHA Table 1 compliant drilling/cleaning method using Milwaukee Tool hollow vacuum bit system
Qualified for Seismic Design Categories A through F
Nationally DOT approved or pending
Made in the USA in accordance with CFR 49 section 50101
Material Properties
Installation temperature range of 43 °F to 110 °F (6 °C to 43 °C)
Fully cured in 7 hours at 75 °F (24 °C) and in 2 hours at 110 °F (43 °C)
AASHTO M235 and ASTM C881, Types I, II, IV and V, Grade 3, Class A, B & C
Low odor, concrete gray formulation
A22-HS1CC / A9-HS1CC Technical Data Sheet
http://atcepoxy.com/wp-content/uploads/TDS-ULTRABOND-HS-1CC-v3.0.pdf
0 notes
z-man69 · 6 years ago
Text
Adhesive Technology: Ultrabond HS-1CC
Features & Advantages
ICC-ES ESR-4094 evaluation report for cracked and uncracked concrete
Code compliant in cartridge and bulk dispensing systems, IBC/IRC:  2018, 2015, 2012 & 2009
Florida Building Code (FBC) Compliant:  2017 & 2014
City of Los Angeles (LABC/LARC) Code Compliant:  2017
Abu Dhabi International Building Code (ADIBC) Compliant: 2013
ICC-ES AC308 and ACI 355.4 assessed for resisting short term loading conditions up to 205 °F (96 °C)
UL Certified – Drinking Water System Components to NSF/ANSI 61 & Lead Free to NSF/ANSI 372
Suitable for core drilled installations in dry or water saturated concrete
Multiple anchor types:  threaded rod, rebar & internally threaded inserts
OSHA Table 1 compliant drilling/cleaning method using Milwaukee Tool hollow vacuum bit system
Qualified for Seismic Design Categories A through F
Nationally DOT approved or pending
Made in the USA in accordance with CFR 49 section 50101
Material Properties
Installation temperature range of 43 °F to 110 °F (6 °C to 43 °C)
Fully cured in 7 hours at 75 °F (24 °C) and in 2 hours at 110 °F (43 °C)
AASHTO M235 and ASTM C881, Types I, II, IV and V, Grade 3, Class A, B & C
Low odor, concrete gray formulation
A22-HS1CC / A9-HS1CC Technical Data Sheet
http://atcepoxy.com/wp-content/uploads/TDS-ULTRABOND-HS-1CC-v3.0.pdf