DXSB Double-Yoke Double-Tuning Adjustable Air Gap Electromagnet
Product Description
The magnetic field is both-way adjustable, the yoke structure a closed magnetic circuit, so it has a good rigidity, magnetic field direction is horizontal, the supporting yoke rise 45°to the ground for operating the sample easily. Apply to Hall effect studies, magnetoresistance effect studies, magnetostriction studies, torque magnetometer, force method magnetometer, VSM, magnetisability measuring equipment, magnetic materials measuring equipment etc.
Names of parts
1:Horizontal yoke2:Vertical yoke3:coil4:Pole Cap Surface5:Pole Cap
6:Handle 7:Pole Sleeve
A:Coil GapB:Pole GapC:Center HeightD:Horizontal distance of DiameterE:Coil Diameter
Main DimensionDXSB Electromagnet Series Main Dimension
ModelPole DiameterABCDEWeight
(mm)(mm)(mm)(mm)(mm)(mm)(Kg)
DXSB-505080/Custom0~8013013020040
DXSB-8080100/Custom0~100175175280135
DXSB-100100120/Custom0~120200200300200
DXSB-130130120/Custom0~120240240380430
DXSB-175175120/Custom0~120310310500630
DXSB-200200120Custom0~120320320550930
DXSB-220220120/Custom0~1203303306001060
DXSB-250250120/Custom0~1203503506701920
DXSB-280280150/Custom0~1503803807202570
DXSB-300300150/Custom0~1504004007403580
DXSB-380380200/Custom0~1504404408506800
Technical ParametersDXSB Double Yoke Double-tuned Air Gap Alterable Electromagnet
ModelPole Diameter(mm) Air Gap Range(mm)Pole Face(mm)Air Gap(mm)Maxium Magnetic Field(T)Power
DXSB-50Φ500-80Φ50101.00.3KW
DXSB-80Φ800-80Φ80200.90.6KW
DXSB-100Φ1000-100Φ60102.02.0KW
Φ100101.5
DXSB-130Φ1300-120Φ60102.53.8KW
Φ100301.2
DXSB-175Φ1750-120Φ80102.46.5KW
Φ100301.8
DXSB-200Φ2000-140Φ80102.610.0KW
Φ120301.9
DXSB-250Φ2500-140Φ120252.312.0KW
DXSB-280Φ2800-140Φ120252.612.0KW
Typical CasesModelKey IndicatorsReference Picture
DXSB-100
1, The electromagnet is a double-yoke double-type structure, oblique 45-degree seat, the direction of the magnetic field on the ground, pole diameter 100mm, line spacing 100mm, adjustable air gap range: 0-100mm. 2, The diameter of the solenoid pole is 100mm. When the air gap is 10 mm, the center magnetic field Hmax? 1.5T; when the air gap is 80 mm, the center magnetic field Hmax? 0.4T. In the center 5 * 5 * 5mm area, the magnetic field uniformity is 1 * 10-5 3, Electromagnet natural cooling structure. In the 80mm air gap 0.4T magnetic field can work for 0.5 hours. 4, The weight of 200KG. 5, Power supply 10A 120V.
DXSB-80
1, The solenoid model for the SB-80 type, the electromagnet for the double-yoke frame structure, inclined 45-degree angle seat, the magnetic field in the horizontal direction, pole diameter 80mm, line spacing 100mm, magnetic field air gap two-way adjustable range 0 ~ 100mm. 2, Electromagnet with a pair of pole, pole diameter Φ80mm. 3, Magnetic field index: air gap is 40mm, the central magnetic field Hmax ≥ 0.5T; 4,Electromagnet bilateral pole open light hole, pole at the hole diameter 5mm; 5, Working time: when the magnetic field air gap is 40mm, magnetic field strength of 0.4T, the continuous working time of 1 hour. 6, Electromagnet Dimensions: 440 * 450 * 360; weight of 100Kg 7, Power supply 10A 60V
DXSB-250
1, The solenoid model for the SB-250 type, the solenoid for the double-yoke frame structure, inclined 45-degree angle seat, the magnetic field in the horizontal direction, the pole diameter of 250mm, line spacing 120mm, magnetic field air gap two-way adjustable range 20 ~ 120mm. 2, Electromagnet with a pair of pole, pole diameter Φ70mm. 3, Magnetic field index: air gap is 50mm, the central magnetic field Hmax ≥ 2.1T; 4, The electromagnet using internal cooling water-cooled structure; when the magnetic field air gap is 50mm, magnetic field strength of 2.1T, the continuous working time of 0.5 hours 5, The weight of the electromagnet is 2200Kg. 6, The user power 75A 180V
0 notes
Text
DX-50 Hall Effect Measurement System
Testable materials:
Semiconductor materials: SiGe, SiC, InAs, InGaAs, InP, AlGaAs, HgCdTe and ferrite materials etc.
Low impedance material: metal, transparent oxide, weak magnetic semiconductor materials, TMR material, ect.
High impedance material: Semi-insulating GaAs, GaN, CdTe, etc.
Hall-effect system components:
This system is consisted of electromagnet, high-precision electromagnet power supply, high-precision constant current source, high-precision voltage meter, gauss meter, connecting cables, standard sample, sample mount and the system software. The system contains specially developed DX-320 constant current source, six semi-microvolt meter and complex switching relays for Hall measurements (Integrally assembled switch). These have greatly simplified the connection and operation of experimental. DX-320 can be used alone as a constant current source or micro-volt meter. The system can be used to measure the carrier concentration, mobility, resistivity, Hall coefficient, and other important parameters of semiconductor material. These parameters must be known in advance to understand the electrical properties of semiconductor materials, so Hall Effect measurement system is an essential tool to understand and study of semiconductor devices and electrical properties of semiconductor materials. The results can be calculated by the software automatically, at the same time, it will get Bulk Carrier Concentration, Sheet Carrier Concentration, Mobility, Resistivity, Hall Coefficient, Magneto resistance, I-V curve and I-R curve measurement parameters.
No.ItemModelDescriptions
1ElectromagnetDXWD-50Magnetic field: 7000 Gauss at 20mm air gap
2High precision
Gauss meterDX-150Accuracy: ± 0.30% of reading/Resolution: 0.01mT Range :0-3T /probe Thickness: 1.0mm/Length 100mm /digital Rs-232 interface data reading software with CDX-800FT probe
3High precision
Power supplyF2031 Digital constant current power supply 10A, 100V, 1000W, RS-232 interface can be CNC polar conversion, resolution: 1mA
4Probe and
sample holder Non-magnetic aluminum bracket 5-70mm adjustable; sample holder fixture (on request)
5System software Adjusting the magnetic field can be digitized and current testing of various material parameters
6Constant current
source
and electric meterDX-320Current output: 0.1nA-50mA,
voltage test: 0.1uV-30V
7Calibration Sample Silicon Sheet/Ga/As, resistance: 300~500Ω
Main technical indicators:
1) Magnetic field intensity: Greater than 7000 gauss (DX-50) Greater than 14000 gauss (DX-100) Magnetic gap 15mm 2) Electric current: 0.1mA~50mA(Expandable to 1A) 3) Measuring voltage: 0.1uV~30V 4) Offers a variety of standard test materials: GaAs, Si etc. 5) Magnetic field minimum resolution: 0.01mT 6) Magnetic field measuring range: 0~3T 7) Resistance Range: 10mΩ~1MΩ 8) Carrier concentration: 103~1022cm-3 9) Mobility: 0.1~108cm2/volt*sec 10) Systematic measurement errors: <2%
▲ with Gauss meter or data acquisition board computer communications ▲ I-V curves and I-R curve measurements ▲ resistivity range :10-6 ~ 1011 Ohm * cm ▲ Resistance Range: 10 m Ohms ~ 1MOhms ▲ carrier concentration: 103 ~ 1022scm-3 ▲ mobility: 102 ~ 107 cm2/volt * sec ▲ fully automated testing, a key processing
DX-50 Hall Effect Measurement System :
https://www.magnetic-instrument.com/hall-effect-system-DX-50.htm
0 notes
Text
DX-100 Hall Effect Measurement System
Testable materials:
Semiconductor materials: SiGe, SiC, InAs, InGaAs, InP, AlGaAs, HgCdTe and ferrite materials etc.
Low impedance material: metal, transparent oxide, weak magnetic semiconductor materials, TMR material, ect.
High impedance material: Semi-insulating GaAs, GaN, CdTe, etc.
Hall-effect system components:
This system is consisted of electromagnet, high-precision electromagnet power supply, high-precision constant current source, high-precision voltage meter, gauss meter, connecting cables, standard sample, sample mount and the system software. The system contains specially developed DX-320 constant current source, six semi-microvolt meter and complex switching relays for Hall measurements (Integrally assembled switch). These have greatly simplified the connection and operation of experimental. DX-320 can be used alone as a constant current source or micro-volt meter. The system can be used to measure the carrier concentration, mobility, resistivity, Hall coefficient, and other important parameters of semiconductor material. These parameters must be known in advance to understand the electrical properties of semiconductor materials, so Hall Effect measurement system is an essential tool to understand and study of semiconductor devices and electrical properties of semiconductor materials. The results can be calculated by the software automatically, at the same time, it will get Bulk Carrier Concentration, Sheet Carrier Concentration, Mobility, Resistivity, Hall Coefficient, Magneto resistance, I-V curve and I-R curve measurement parameters.
No.ItemModelDescriptions
1ElectromagnetDXWD-100Pole dia.: 100mm.
Magnetic field:
17000 Gauss at 10mm airgap
10000 Gauss at 25mm airgap
8000 Gauss at 30mm airgap
Uniformity area: 1% in 6x6mm at 10mm airgap
Weight: 110 kgs
2High precision
gaussmeterDX-150Accuracy: ± 0.30% of reading/Resolution: 0.01mT range :0-3T /probe Thickness: 1.0mm/Length 100mm /digital Rs-232 interface data reading software with CDX-800FT probe
3High precision
Power supplyF2030Digital constant current power supply 10A, 100V, 1000W, RS-232 interface can be CNC polar conversion, resolution: 1mA
4Probe and
sample holder Non-magnetic aluminum bracket 5-70mm adjustable; sample holder fixture (on request)
5System software Adjusting the magnetic field can be digitized and current testing of various material parameters
6Constant current
source
and electric meterDX-320Current output: 0.1nA-50mA, voltage test: 0.1uV-30V
7CryostatDXE-1280K-500K
8Temperature regulatorDX-202Control temp. range:(80k-720k)
9Vacuum PumpK25
Main technical indicators:
1) Magnetic field intensity: Greater than 14000 gauss at 20mm air gap 2) Electric current: 0.1mA~50mA(Expandable to 1A) 3) Measuring voltage: 0.1uV~30V 4) Offers a variety of standard test materials: GaAs, Si etc. 5) Magnetic field minimum resolution: 0.01mT 6) Magnetic field measuring range: 0~3T 7) Resistance Range: 10mΩ~1MΩ 8) Carrier concentration: 103~1023cm-3 9) Mobility: 0.1~108cm2/volt*sec 10) Systematic measurement errors: <2%
▲ with Gauss meter or data acquisition board computer communications ▲ I-V curves and I-R curve measurements ▲ resistivity range :10-6 ~ 1011 Ohm * cm ▲ Resistance Range: 10 m Ohms ~ 1MOhms ▲ carrier concentration: 103 ~ 1022cm3 ▲ mobility: 102 ~ 107 cm2/volt * sec ▲ Temperature regulation 0.1K ▲ Temperature Range: 80K-500K (optional) ▲ fully automated testing, a key processing
DX-100 Hall Effect Measurement System : https://www.magnetic-instrument.com/hall-effect-system-DX-100.htm
0 notes
Text
Hall Effect Measurement System
Introduction
The electrical transport test system is one fully automated test system, which intergrates Hall effect, magnetoresistance, IV characteristics test in one machine. This system takes some problems which users often ignore, such as instrument configuration, circuit wiring (including room temperature and low-temperature wiring) into consideration, selects the Keithley electrical measuring instruments. The magnetic field can adopt electromagnet or liquid helium superconducting magnet based on user’s requirement, equipped the smart measurement sample rod, plus a special fully automated test software, allowing users to quickly and easily measure sample and obtain accurate and reliable data. Addition, there are a variety of low-temperature options, and can transform according to the user's existing instrumentation and the special requirements of the software. DX3000 series hall effect measurement system is a powerful tool for the resaearch of materials’ electrical transport properties.
Basic configuration:U.S. Keithley instrumentationSystem
(resistance range)Source meterVoltmeterAmmeterHost computerMatrix cardElectrometerCommu
nication Interface
2400622027002182A648570017709701271526514488B
Standard
(10mΩ-10MΩ)1111
High sensitivity
(0.1mΩ-10MΩ)11111
High voltage and impedance
(0.1mΩ-100GΩ)1111221
Magnetic partMagnetic field rangeMagnetic bodyCooling deviceMagnetic field measurementPowerSoftware
0~1T@10mmDX-100 electromagnetWithoutDX-160 gauss meter
Precision: 0.2%DX-2030, 1KWFull automatic data processing and drawing
0~2.4T@10mmDX-130 electromagnetWithoutDX-180 gauss meter
Precision: 0.05%DX-10030, 3KWFull automatic data processing and drawing
0~2.6T@10mmDX-180 electromagnet8KW water chillerDX-180 gauss meter
Precision: 0.05%DX-10050, 5KWFull automatic data processing and drawing
Low temperature portion (optional)Temperature RangeCooling bodyTemperature control device
80~450KLiquid nitrogen thermostatTC202
4~500KCycle refrigeratorTC202
1.6~325KCryogenic low temperature systemTC202
45~325KCTI small refrigeratorTC202
Main features:
Using plug-sample cards, easy to install;
One standard configuration can simultaneously measure two samples, 4 samples can be measured simultaneously by adding optional devices;
Resistance measurement range: 0.1mΩ~100GΩ(High voltage and impedance system);
Different Hall effect and resistance measurements under different current and magnetic field;
Testing and calculation process performed automatically by the software, which gives the intermediate data and the curve at the same time.It will save you a lot of time;
System provides high stability of the magnetic field for a long time,zero magnetic field can be smoothed;
Electromagnet power supplybuilt in precision Gauss Meter, high field control speed;
Choosing low-temperature device,Hall effect and resistance measurements can be performed at different temperatures.
Testable material:
Semiconductor materials: SiGe, SiC, InAs, InGaAs, InP, AlGaAs, HgCdTe and Ferrite materials, etc.
Low impedance material: metal, transparent oxide, weak magnetic semiconductor materials, TMR materials, etc.
High impedance material: semi-insulating GaAs, GaN, CdTe,etc.
Basic function:
Measurement of Hall Effect, magnetic resistance, curves of I-V and R-T .
Parameters to be measured: Hall Effect- sheet resistance, resistivity, Hall coefficient, conductivity type, Hall mobility, carrier concentration;
Magnetic resistance effect: R, △R, (△R/R)%, (△R/R0)%
I-V curve: I-V curves at different temperature and magnetic field.
R-T curve: Under fixed magnetic field, the curves for resistance changes at different temperature.
R-H curve: Under fixed temperature, the curves for resistance changes at different magnetic field.
Main technical indexes:
Sample size
Small size sample card: 12*12 mm2
Large size sample card: 50*50 mm2
Probe sample card: 1×1mm2~30×30mm2
Sample measurement method
Hall effect samples: Si, GaAs, ect.
Resistance and I-V samples: 4 wire or 6 wire method
Magnetic field environment
Model
IndexDX-100DX-130DX-180
Pole diameter60mm(optional)100mm(optional)120mm(optional)
Air gapRoom temp.
10mmLiquid nitrogen thermostat 24mm
optionalARS refrigerator
40mm
optionalRoom temp.
10mmLiquid nitrogen thermostat 24mm
optionalARS refrigerator
40mm
optionalRoom temp.
10mmLiquid nitrogen thermostat 24mm
optionalARS refrigerator
40mm
optional
Max. magnetic field1.5T0.9T0.6T2.5T1.5T1.0T2.7T2.0T1.4T
Uniformity±1%±1%±1%
Temperature environment (optional)
No liquid helium superconducting magnet system, 1.6K~325K;
Liquid nitrogen thermostat options: Standard liquid nitrogen thermostat, 80K~325K; High temperature liquid nitregen thermostat, 80K~500K;
Cycle refrigerator options: Standard 4K refrigerator system, 4K~325K; High temperature 4K refrigerator, 4K~700K; Standard 10K refrigerator system, 10K~325K; High temperature 10K refrigerator, 10K~800K; Minisize refrigerator system, 45K~325K;
Electrical properties
Under the following typical test conditions:
Sample power consumption less than 1mV, under this condition, let excitation reach the maximum recommended current and voltage in system configuration;
Sample temperature 295K;
Sample seat without leak current;
The reistance of each test lead 25Ω;
Voltage usage effectiveness of measurement electrical resistivity (V_out/V_in) should be 0.1 approx. for Vanderbit sample and should be 0.5 approx. for hall sample;
Sample shape correction factor 1;
Magnetic field and sample thickness measurement uncertainty should be within 1%;
Magnetic field/sample thickness should be 1T/mm, note the measured maximum carrier concentration is approximately proportional to this value, so stronger magnetic field and thicker sample could improve the measurement range.
Hall Effect Measurement System :
https://www.magnetic-instrument.com/hall-effect-system-DX-3000.htm
0 notes
Text
3 Axis Helmholtz Coil
Helmholtz Coil, homogeneous area is big, and the use of the space is open, also easy to handle. It Can achieve that one-dimensional, two-dimensional and three-dimensional combination of magnetic field, provide ac and dc magnetic field, and electric current and magnetic field can have a good linear relationship. It apply to the institutes, institutions of higher learning and enterprises material or magnetic detection experiment, applied to materials, electronics, biological, medical, aerospace, chemical, applied physics and other subjects, Its main use: produce standard magnetic field; Offset and compensation of the earth's magnetic field, the magnetic environment simulation, judgment of magnetic shielding effect, electromagnetic interference simulation experiment, hall sensor and all kinds of magnetometer calibration, biological magnetic field research and the study of the magnetic properties of the material.
ModelMain technial parametersReference Picture 3DXHC10-100Magnetic field direction X, Y, Z axis orthogonal to each other, the highest magnetic field strength of each axis is 100 Gs; Minimum average diameter is 200 mm; Uniform area: Φ25 mm; Uniformity: 0.1%; Power supply: 300-800 W. 3DXHC15-30Magnetic field direction X, Y, Z axis orthogonal to each other, the highest magnetic field strength of each axis is 30 Gs; Minimum average diameter is 300 mm; Uniform area: Φ40 mm; Uniformity: 0.1%; Power supply: 120 W/each axis. https://www.magnetic-instrument.com/3-axis-helmholtz-coil.htm
0 notes
Text
Magnetic Declination Testing System
Introduction
A single Helmholtz coil can be used to measure the magnetic moment M produced by the permanent magnet in the magnetization direction. The magnetic moment M can be obtained through the relational expression M=KH×Φ, in which KH is the Helmholtz coil constant, while the Φ is the magnetic flux of the magnet induction to the coil. As for the quality inspection for the permanent material samples after being magnetized, Helmholtz coil is adopted and it is getting quite popular and universal. It is extremely important for the designed one-dimensional and three-dimensional Helmholtz Coil to participate in the mutual parameter transmission with its international peers.
Through the efforts of the company's collective wisdom, DX-2100AM magnetic declination measuring device was completed and can be put on the market as a new product. Compared with the original prototype, this enquipment imporves is the design of the machine body, add a pneumatic push sample structure for the separation of large rare earth permanent magnet sample, and coil constants K of XY axis coils are designed to be under 0.015cm. All of these meet the needs of customers at home and abroad. As the equipment does not involve the use of graphic record, we change the computer configuration to laptops, mainly used as the record of the test samples, and all the recorded parameters can be directly printed out.
ConfigurationNo.ModelItem NameQtyUnit
1DX-2100AMmagnetic declination test host1set
2DXHC1503-axial helmholtz coil1set
3DX-2100magnetic declination testing software1set
4M4200Lenove PC1set
5HP1007HP printer1set
6NonstandardSpecial working platform1set
Technical Parameters1. DX-2100AM magnetic declination test host1) three-channel fluxmeter
Fluxmeter range: 1mWb/10mWb/100mWb/1000mWb, four gears, accuracy: 0.5%;
Fuxmeter resolution: 0.01%, 0.1uWb min.;
Input impedance corresponding range: 1kΩ/10kΩ/100kΩ/1MΩ;
Drift: 1uWb/min (corresponding to 10mWb test range after adjusting stably) .
2) Host function
Diretly display the flux of three-channel fluxmeter;
Directly display magnetic declination θz of the tested sample;
Comprison between θz and the setting value, easy to judge qualifed or unqualified and classify high precision product;
Stand-alone test or connect to PC with RS232 interface and automatically record test data ;
Repeatability and reproducibility of magnetic moment M and magnetic declination θz is less than 10%.
2. DXHC150 3-aixal helmholtz coils (round-shape)
XY coil constant designed as: 0.015 Wb*cm/V*s, calibration accuracy: better than 0.5%;
Z coil constant designed as: 0.05 Wb*cm/V*s, calibration accuracy: better than 0.5%;
Coil orthogonal angle: better than ±0.2°;
Main axial coil (Z coil places up and down, easy to improve the test accuracy of magnetic declination);
Test sample range: a. 30mm3~150mm3 (homogeneous area: 0.3%); b. 30mm3~30mm3 (homogeneous area: 1.0%).
https://www.magnetic-instrument.com/magnetic-declination-tesing-system.htm
0 notes
Text
laboratory Electromagnets
DXDJ Multipole Laboratory Electromagnet
Product Description
Multi-pole electromagnet has four poles, five poles, six poles, eight poles electromagnet iron; Mainly used in multi-polar magnetizing magnetization, radial gradient magnetic field, magnetic guidance of rotating magnetic field, etc .; Designed and manufactured according to the user's requirements.
Typical CasesNo.Main technical parametersReference Picture
1Pole diameter: 30mm,
Pole Face: 15mm,
Air gap: 20mm,
Magnetic field: 0.15T,
The angle between incident light and reflected light is 90º,
Magnet with two 8A 50V power supply, each winding resistance is 3Ω;
2Poles: 40 * 20mm,
Air gap: 20mm,
Magnetic field: 0.13T,
Power: 3A125V;
3Fixed air gap: 70mm, with a pair of 40mm poles,
When the air gap is 70mm, the magnetic field is 0.1-0.15T;
Power: Two 20A20V power supply.
4Pole diameter: Φ32mm,
Pole diameter: Φ32m,
Line package spacing: 80mm,
Adjustable quadrupole air gap, adjustable range is 40-80mm;
Quadrupole used in series, the current is 1A, the surface magnetic field of the magnetic pole is 300Gs.
https://www.magnetic-instrument.com/laboratory-Electromagnets-5.htm
0 notes
Text
laboratory Electromagnets
DXEG Clamp Laboratory Electromagnet
Product Description
Clamp-type electromagnet bipolar protruding wire package outside, shape, such as clamp, usually used to produce in-plane magnetic field, suitable for microscope, probe station, space limited, magneto-optical experiments, magnetic mineral powder screening and other special use environment. Clamp-type electromagnets are mostly customized, and they can be designed according to the user's conditions and magnetic field requirements.
Typical CasesModelMain technical parametersReference Picture
DXEG-1Center magnetic field strength: 2800Gs;
Polar face size: 6*12mm;
Magnetic field air gap: 10mm;
Coil diameter: 70mm;
Power Supply: 60W
DXEG-2Center magnetic field intensity: 3500Gs;
Polar face size: 12*12mm;
Magnetic field air gap: 15mm;
Coil diameter: 100mm;
One-side pole punch through hole;
Power Supply: 270W
DXEG-3Center magnetic field strength: 7000Gs;
Polar face size: 20*20mm;
Magnetic field air gap: 10mm;
Coil diameter: 120mm;
Power Supply: 720W
DXEG-4Center magnetic field strength: 2200Gs;
Polar face size: 5*20mm;
Magnetic field air gap: 15mm;
Coil diameter: 80mm;
Power Supply: 220W
laboratory Electromagnets : https://www.magnetic-instrument.com/laboratory-Electromagnets-6.htm
0 notes
Text
laboratory Electromagnets
1, The electromagnet is made of specially made silicon steel sheet. The E type yoke is a fixed air gap, and the ends of the pole are assembled with excitation wire packages. The magnet is placed vertically and the magnetic field is in the vertical direction. Polar electromagnet square 45*45mm2, air gap is 10mm. 50Hz~499Hz magnetic field can be adjusted continuously, the maximum magnetic field can reach 1.0T (amplitude value, same below). The 100Hz magnetic field reaches a maximum value of 0.5T; at 200Hz, about 0.2T. In 499Hz, the magnetic field up to 200~300Gs
2, Uniform area: in the center of the magnetic field 10*10mm3, the magnetic field uniformity △H/H is about 0.03.
3, Working hours Under low current density, the electric operation is carried out, and the line package is cooled by air cooling. When the magnetic field is rated as the highest rated value, the temperature rise for a long time is less than 20 degrees centigrade.
4, AC power, power 12KW. The highest output voltage of single-phase output is 300V, the rated output current is 40A, and the load regulation rate is 0.5%. Voltage and frequency adjustable; frequency adjustable range 50~499Hz; display interface: voltage, current, frequency and power indicator.
5, Working hours Under low current density, the electric operation is carried out, and the line package is cooled by air cooling. When the magnetic field is rated as the highest value, the temperature rise for a long time is less than 20 degrees centigrade.
6, The net weight of electromagnets is about 150Kg.
laboratory Electromagnets :https://www.magnetic-instrument.com/laboratory-Electromagnets-7.htm
0 notes
Text
laboratory Electromagnets
DXDY Shaped electromagnet/Magneto-optical electromagnet
Product Description
We can be based on user requirements designed to produce all kinds of special-shaped, special purpose electromagnet. Can be based on different use, different experimental requirements, different working environment, and with different equipment supporting the design of the assembly; can make the magnet to maintain the highest possible magnetic field, to achieve the greatest deformation.
Typical CasesModelMain technical parametersReference Picture
DXDY-751, Structure: The magnetic field of the three magnetic coils of the electromagnet is the same in the axial direction, and the middle line bag is hollow, fixed on the track, and the two sides of the line bag can move along the track to facilitate the placement of the sample. When the three line packages are close together, the magnetic circuit is closed. Magnetic field space diameter is 200mm, length 200mm, magnetic field direction parallel to the ground.
2, the highest magnetic field H ≥ 0.1T.
3, power supply 10A 120V
DXDY-601, Structure:Electromagnetic single wire package double yoke upright seat, horizontal magnetic field direction, wireless package side pole punch hole, aperture 5mm. Upper yoke iron microscope lens hole, aperture 30mm;
2, magnetic field air gap is 30mm, the highest magnetic field H ≥ 0.45T.
3, power supply 20A 20V
DXDY-1751, The electromagnet structure adopts a double-wire wrap-around magnetic circuit with a fixed air gap and the magnetic field is in the horizontal direction. The electromagnet is placed on the floor vehicle and can be moved back and forth on the track.
2, As shown in the figure, the pole tip is approximately 140mm from the top of the wire package, the magnetic pole area is approximately 80*80mm2, and the fixed air gap is not less than 65mm. The magnetic pole and wire package dimensions guarantee incident and reflected light at 90° in the magnetic field. Adoption.
3, in the air gap of ≥ 65mm with the use of power, in the maximum power, the magnetic field ≥ 0.5T, the magnetic field in the center of the air gap has a uniform area of 20 * 20mm2 or more.
4, power supply 5KW
DXDY-801, Structure: Electromagnetic single wire package double yoke vertical seat, vertical magnetic field direction, wireless package side pole head shot hole, aperture 40mm, pole surface aperture 10mm. Lower pole adjustable;
2, magnetic field air gap is 10mm, the highest magnetic field H ≥ 1.0T.
3, power supply 20A 20V
laboratory Electromagnets :
https://www.magnetic-instrument.com/laboratory-Electromagnets-8.htm
0 notes
Text
laboratory Electromagnets
Rotating magnets, the magnetic field can be rotated 360° around the axis of rotation, can be equipped with a stepper motor to accurately control the rotation of the magnet, arbitrarily set the rotation angle, programmable control forward rotation and travel time. The controller's angular resolution is 0.01 degrees, the mechanical step angle is 0.1 degrees, and the repeatability is 0.05 degrees.
laboratory Electromagnets : https://www.magnetic-instrument.com/laboratory-Electromagnets-9.htm
0 notes
Text
Adjustable magnetic field of permanent magnet
Permanent magnets produce a constant magnetic field has a very favorable conditions, but the structure of the single to its application subject to certain restrictions. Our company is committed to the development of a variety of adjustable magnetic field permanent magnet, so that the air gap is adjustable, the magnetic field strength adjustable, uniform area stability, so that the function of the permanent magnet closer to the electromagnet, making it more widely used.
No. NameCase StudyPictures
1Adjustable permanent magnet air gap◆ Magnetic field air gap is adjustable, when the poles distance increases when the magnetic field is weakened.
◆ To change the air gap to change the magnetic field, simple structure, easy to operate.
◆ Pole diameter 100mm, adjustable air gap range of 10-100mm, magnetic field adjustable range of 0.14 ~ 0.9T.
2Adjustable low field magnet
◆ Magnetic field air gap is fixed, the relative position of the pole unchanged, to change the magnetic circuit channel width of the way to change the magnetic field. ◆ Dimensions: 140 * 65 * 180mm pole diameter Φ40mm, air gap 15mm Weight: 5Kg ◆ Center magnetic field 16 ~ 590Gs continuously adjustable, adjust the accuracy of 1Gs ◆ Center 10 * 10 * 10mm space uniformity 590Gs = 0.16% 16Gs = 6%
3Broken yoke magnet
◆ The broken yoke permanent magnets adjust the center magnetic field strength by the distance between the side yoke and the yoke connection and the disengagement distance. ◆ Dimensions: 210 * 170 * 200mm ◆ Pole surface diameter: Φ140mm air gap 30mm ◆ Weight: 30Kg ◆ Adjust the range of 3230 ~ 3450Gs, adjust the fineness of 1Gs; ◆ Magnetic field uniformity: Φ30 * 10 space of 0.02% Φ60 * 20 space of 0.11%
4Pair of adjustable magnetic field of permanent magnet magnetic axis
◆DX-1.2 permanent magnet does not change the relative position of the magnetic pole under the conditions, with the magnetic circuit to adjust the magnetic field, to achieve the function of the electromagnet, without the need for excitation power. It is light weight, easy to operate, you can manually adjust the magnetic field; reserved input shaft, but also with the reducer or stepper motor connection, electric adjustment magnetic field ◆ Strength, adjustment accuracy of up to 1 (Gs). ◆ Dimensions 200 * 150 * 200 (MM) Weight 13 (Kg) ◆ Double magnetic axis permanent magnet, magnetic field direction, the pole surface diameter Φ8mm, adjustable air gap range of 5mm-25mm. When the air gap is 5mm, the maximum magnetic field 1.2T, magnetic field adjustable range 0-1.2T.
5Double magnetic axis adjustable permanent magnet
DX50-1 permanent magnet: ◆ Magnetic surface diameter: 50mm, ◆ Air gap adjustable range: 5-100mm, ◆ The magnetic field is adjustable, the working air gap is not changed when the magnetic field is adjusted, the minimum adjustment fineness of the magnetic field is less than 1Gs, the magnetic field is continuously adjusted, and the zero-crossing is reversed; ◆ When the working air gap is 5mm, the magnetic field range is 0~ plus or minus 1.0T; when the air gap is 10mm, the magnetic field range is 0~ plus or minus 0.5T; when the air gap is 25mm, the magnetic field range is 0~ plus or minus 0.2T..
https://www.magnetic-instrument.com/Permanent-Magnet-6.htm
0 notes
Text
Magnetic Field Of Permanent Magnets
The features of constant magnetic field:
* Without power supply, saving energy, without heating when using for long time, small volume and linght weight, low price; * Air gap fixed with good rigidity, stable magnetic field, could be used as standard magnetic field; * Wide application, could be chose according to the different requirements of instrument and device. It is the best choice for devices that require high precision, such as NMR.
We could customize different shapes permanent magnet according to customers’ special requirements.
ModelPole Face Diameter (mm)Air gap (mm)Magnetic field in the center (T)Dimension of uniform field (mm)Uniformity
(H/H)Shape
(mm)Weitht
(Kg)
DX4010-0140100.1Φ6*60.001Φ82x1022
DX4010-0240100.2Φ6*60.001Φ84x1022
DX4010-0340100.3Φ6*60.001Φ84x1022
DX4010-0440100.4Φ6*60.001Φ84x1022
DX4010-0540100.5Φ6*60.001Φ84x1022
DX4010-0640100.6Φ6*60.001Φ84x1022
DX4010-0740100.7Φ6*60.001Φ84x1022
DX4008-084080.8Φ6*60.001Φ84x1153
DX4006-094060.9Φ6*60.001Φ82x1364
DX4006-103061Φ5*50.001Φ82x1364
DX4006-113061.1Φ5*50.001Φ82x1364
https://www.magnetic-instrument.com/Permanent-Magnet-1.htm
0 notes
Text
Magnetic Field Of Permanent Magnets
Magnet Machine:Magnetometers,Hysteresis Graph Test System,Magnetic Field Tracer,Teslameter
Force method magnetometer,Magnetic Source,Magnetic Field Coil,DC Power Source
Product Detail:
Constant magnetic field of magnets
Permanent Magnet Magnetic Field Source Features:
1. No power supply, energy saving, long-term use does not heat, small size, light weight, low cost. 2. Air gap fixed rigidity, magnetic field stability, can do standard magnetic field use. 3. Wide range of use, you can choose according to the different requirements of instruments and equipment permanent magnets. For high-precision magnetic field source requirements such as nuclear magnetic resonance instrument, permanent magnet magnetic field source is the best choice. 4. We can according to the user's specific requirements of the magnetic field design of special-shaped permanent magnet.
No.ModelPolar diameterAir gapMagnetic field
(mm)(mm)(T)
1DX5010-0450100.4
2DX5010-0650100.6
3DX5010-1150101.1
4DX5020-0450200.4
5DX5020-0750200.7
6DX10020-06100200.6
7DX10020-08100200.8
8DX10020-10100201
9DX10030-05100300.5
10DX10030-07100300.7
12DX10030-11100301.1
13DX14040-05140400.5
14DX15020-14150201.4
15DX200110-052001100.5
https://www.magnetic-instrument.com/Permanent-Magnet-1.htm
0 notes
Text
Magnetic Field Of Permanent Magnets
The features of constant magnetic field:
* Without power supply, saving energy, without heating when using for long time, small volume and linght weight, low price; * Air gap fixed with good rigidity, stable magnetic field, could be used as standard magnetic field; * Wide application, could be chose according to the different requirements of instrument and device. It is the best choice for devices that require high precision, such as NMR.
We could customize different shapes permanent magnet according to customers’ special requirements.
ModelPole Face Diameter (mm)Air gap (mm)Magnetic field in the center (T)Dimension of uniform field (mm)Uniformity
(H/H)Shape
(mm)Weitht
(Kg)
DX4010-0140100.1Φ6*60.001Φ82x1022
DX4010-0240100.2Φ6*60.001Φ84x1022
DX4010-0340100.3Φ6*60.001Φ84x1022
DX4010-0440100.4Φ6*60.001Φ84x1022
DX4010-0540100.5Φ6*60.001Φ84x1022
DX4010-0640100.6Φ6*60.001Φ84x1022
DX4010-0740100.7Φ6*60.001Φ84x1022
DX4008-084080.8Φ6*60.001Φ84x1153
DX4006-094060.9Φ6*60.001Φ82x1364
DX4006-103061Φ5*50.001Φ82x1364
DX4006-113061.1Φ5*50.001Φ82x1364
https://www.magnetic-instrument.com/Permanent-Magnet-1.htm
0 notes
Text
Electromagnet Power Supply
Main Functions and Features
1. Using a 24bit ADC and DAC analog as front-end and back-end interfaces.
2. Using ARM + DSP to achieve dynamic digital control.
3. Using 5.7 inches (320 × 240) large size LCD to display real-time power supply status.
4. Offering five output control modes, able to adapt to different application environments:
Set by the keyboard;
Controlled by an analog voltage;
Controlled by the computer via UART interface;
Controlled by a computer via the GPIB interface (Optional);
Controlled by a computer via the USB interface (Optional);
Using preemptive design, don’t need to specify control mode through panel .
5. Bipolar output, non-contact commutation, current continuous zero crossing:
Output current, voltage four -quadrant operation (especially for inductive load);
The change rate of the output current can reach 200A / s, for reactive load, the power automatically limit the rate according to current and power.
6. Supporting to connect with the gauss meter via a serial interface.
7. Automatic control mode for the magnetic field. Directly enter the target magnetic field strength through the buttons on the panel of power supply, the power supply automatically adjust the output current according to readings of built-in gauss meter to stabilize the magnetic field to the setting value.
8. Using a low-power standby mode, supports host computer to remotely turn power on and off, without panel operation.
9. A variety of protection functions. Consider the states of electricity and cooling, module status of multiple factors , to provide comprehensive protection for power and fault status is displayed directly on the LCD screen, the user check the reason:
Input power supply undervoltage , overvoltage protection;
Input power supply phase loss protection;
Input power supply failure protection (internal protection to absorb the inductive load anti- irrigation energy);
Cooling water failure protection, internal overheating protection, condensation inside the machine protection;
Module undervoltage protection;
Module overcurrent protection;
Module over power protection. Electromagnet:https://www.magnetic-instrument.com/magnetic-source-9-2.htm
0 notes
Text
DX Sereies Electromagnets
DX Series electromagnet can generate a adjustable magnetic field by changing pole cup and adjusting the air gap. The main applications include: magnetic optical studies, hysteresis loop measurement, the magnetic field annealing, Hall effect measurement studies, magnetic susceptibility measurement, magnetic resonance imaging studies , biology research, ect.
DX series electromagnet cooperates with our electromganet power supply to form electromagnetic field control platform system. This system achieves a rapid and uniform magnetic field scanning commutation through true bipolar power output, thereby avoiding thant the problem of zero intermittent reversal occurs when using a non-continuous power supply.
Electromagnets : https://www.magnetic-instrument.com/magnetic-source-9-1.htm
0 notes