Heat Shrink Outdoor Termination Kit | Cable Accessories | Cable Jointing & Termination Kits
“Energy connectivity with reliability & constancy, for everyone and everywhere.”
We believe in energy connectivity with reliability & constancy, for everyone and everywhere. Our aim is to make innovative Energy connectivity solutions available to everyone at the time it matters.
Worldwide, Heat Shrink Outdoor Termination ( Heat Shrink Terminations ) is widely used to Joint and Terminate MV electric cables. The technology deploys Heat Shrink tubings and moulded shapes.
Description
Heat Shrink Tubings
Heat Shrink Outdoor Termination Kit uses speciality polymers, extruded into tubings and moulded into various shapes for providing a range taking, long lasting, easy to install technique for Jointing and Terminating MV solid dielectric and paper insulated cables.
The formulation uses polyolefins mixed with various chemicals to make it suitable for use over cables. The following process is followed:
Moulded Shapes
Generally, the moulded shapes are designed to insulate, provide environmental seals, anti- tracking surfaces and creepage extensions. These are normally injection moulded and expanded using SPM’s and special mandrels / fixtures.
Conductor Connection
The conductors used for cables are generally aluminium or copper. For joining / terminating these conductors the following technologies are used for underground cables:
Crimping
Thermal Welding
Mechanical Connectors
Insulation Piercing Device (LV)
PCA Cable Joints are designed to accommodate crimp and mechanical connectors.
Designs
Standard kit designs are based on cables conforming to IEC / IS standards. PCA excels in designs of customised cable accessories as per the application and need of its customers.
Key variables necessitating customisation :
Cable dielectric
Cable construction and dimensions
Electric stressSystem fault levels
Earthing parameters Application
FAQ –
Q- What is the manufacturing process of a heat shrink terminator?
Ans– The special polymers have been used in the manufacturing process of the heat shrink terminator. These polymers have mixed with different cables to make suitable and valuable cables. On the other hand, the manufacturing of heat shrink Terminationincludes the following steps:
Compounding
Extrusion
Beaming
Expansion
Q- What are the uses of the heat shrink terminator?
Ans-The heat shrink terminators help protect the cables. Furthermore, it is suitable to joint and terminates MV cables. The technology is beneficial in the case of molded shapes and heat shrink tubings.
Q- Which key variables are required for the customization process?
Ans– According to the IS/IEC standards, the design of the heat shrink Terminationis based on the standard kit designs prepared by the team, which is according to the IS/IEC standards. Furthermore, it includes the following variables are:
Cable dielectric
Cable construction and dimensions
Electric Stress System for checking the fault levels
The parameters to check out the earthing application
Q- What are the sizes in which the cable is available?
Ans– Heat Shrink Terminators come in different sizes. Furthermore, according to sq. mm, the cable size is 4-35, 50-120, 150-240, 300-400, 500-630, and 800-1000. The client can get the Terminationaccording to their demand.
Q- What are the techniques that have used in making underground cables?
Ans– The conductors are of aluminum or copper. Moreover, the following technology has used for the manufacturing of underground cables includes:
Crimping
Thermal Welding
Mechanical Connectors
Insulation Piercing Device (LV
Categories: CABLE ACCESSORIES, CABLE JOINTING & TERMINATION KITS Tags: Heat Shrink Outdoor Termination, Heat Shrink Terminations, Outdoor Termination Kit
0 notes
pcatechnologies · 3 years
Text
Medium Voltage Overhead Line Cover
PCA’s Medium Voltage Overhead Line Cover (POLC) provides insulation to help prevent electrical outages caused by trees or wildlife coming into contact with overhead distribution lines. It is designed to insulate existing bare conductors without costly conductor replacement expenditures. It is used up to 36 kV. It comes with in-built mastic sealing. It is available in Red colour.
Features:
♦ Anti-tracking
♦ Service temperature: ‐40°C up to +90°C
♦ UV Resistant
♦ Moisture, Corrosion & Chemical resistant
♦ Superior abrasion resistant
♦ Easy and quick installation
Technical Specifications:
Ordering Information:
Categories: CABLE ACCESSORIES, HEAT SHRINK MOULDED COMPONENTS
0 notes
pcatechnologies · 3 years
Text
10 Tips For Proper Installation Of Screened Separable Connectors
Oct 11, 2020  pctechman  T Shaped Screened Separable Connector  0 Comments
Ensure semi-con cutback dimensions are accurate and there are no cuts on the insulation.
Do not nick or cut the shield, insulation or conductor when preparing the cable. This can lead to over-heating and dielectric failure.
Brush conductors before inserting them into the connector to remove any oxide layers.
Do not remove the grease from connectors. It is there to help break up the oxide film and improve current transfer.
Use the correct tool and die and make the recommended number of crimps when installing the compression connector. Rotate successive indents 90 or 180 to prevent distortion.
Use supplied grease only; other lubricants may separate during thermal cycling and leave stuck elbows.
Do not use silicon oil on separable connectors. Oil is for permanent installations such as splices and live-front terminators.
Ensure air release while installing back insulator.
Ensure no dust particles exist on the connector assembly or on cable insulation surface during installation.
Follow the installation guide, recommended work practices and be safe.
know more about Proper Installation Of Screened Separable Connectors
0 notes