Ambtronics Engineers Manufacturer of Gas Detector ,Flame Detector, Gas Detection System,Portable Gas Detector and Gas Leak Detector.
Don't wanna be here? Send us removal request.
Link
0 notes
Link
0 notes
Link
0 notes
Link
#iot security#internet of things#iot services#iot solutions#industrial iot#remote access#secure remote access#industrial automation
0 notes
Photo
As the demand for O2 (Oxygen) increases in India🇮🇳 during this pandemic😷, the need to check the purity of oxygen from oxygen generators also rises ⬆️ The Panel Mount Oxygen Analyzer (GA-3511-PM) is devised to check oxygen purity from oxygen generators from 0-100% V/V. So, if you are looking to verify oxygen purity from your oxygen generator, look to Ambetronics Engineers Pvt. Ltd. Website URL: https://lnkd.in/ewV5Cyj Technical Datasheet: https://lnkd.in/eSP5XsM For more details about our analyzers, get in touch with us at: 📧 [email protected] 📞+91-93207 37646 (WhatsApp) ☎️+91-22-6167-3056 🌐 www.ambetronics.com 📍Branch offices: Bharuch | Delhi | Pune | Bangalore | Ahmedabad #OxygenAnalyzer #OxygenPurity #oxygenconcentrator #oxygenshortage #oxygengenerator #oxygen #covid19 #coronavirus #pandemic
0 notes
Link
0 notes
Link
0 notes
Text
UV & IR based Flame Detectors | How to avoid Fire in Industries? | How Did Flame Detector Work?|Ambetronics
Flame watcher is a state-of-the-art Flame Detectors series having different ranges of UV & IR Flame Detector.
Flame detectors are the first line of defense in fire detection and extinguishing system. Which provides an excellent safety measure against flame, preventing it from turning into a catastrophic fire, saving lives and assets.
Flame Detectors is a Microcontroller based fully digitally addressable device. It utilizes smart sensor technology for Accurate Flame detection. It utilizes a sophisticated algorithm that offers excellent false alarm immunity. Provided with high sensitivity, it is capable of detecting hydrocarbon-based flame within a few seconds and prevents human loss as well as industrial loss.
Flame Detectors Provide Industrial standard output such as 4–20mA / 0–10V, relays, RS-485. It is HART addressable and connectivity is provided via Bluetooth and Wi-Fi/ LoRa /IoT for the mobile alert. It is also equipped with a built-in data logging facility, which provides a Date-time stamped report of important / alarm events for further analysis. It has a Minimum of 90 cones of vision on the Horizontal & vertical axis and can detect fire up to 65 meters within a few seconds. Its performance can be tested by using a test Lamp (FTU-3311-FLP).
UV/ IR Flame detector can be integrated with PLC/SCADA system. It is designed in such a way that, It is Universally Compatible, which enables it to be connected to any Fire alarm panel or any other control panel of any make, So in case of fire, it alerts the nearby personnel, generates a factory-wide alarm, and initiate preventing action such as sprinkler/form-based extinguishing system, evacuation protocol, etc. It is enclosed in Explosion-proof housing of Aluminium (LM 6) and stainless steel (SS316) material making it Applicable in Hazardous Environment. It also available in small size enclosures (JB 90-LM/SS) that can be used where an application is size oriented. For the indoor office, based non-hazardous environment compact size weatherproof (WP) package is also available. The UV/IR Flame Detectors is designed to meet the requirements of standard EN54–10, FM/ANSI, and NFPA72 (In Process). Flame detectors possess Approvals/certificates such as [ATEX, CE, PESO, CIMFR and ISI].

How Did Flame Detectors work?
Flame Detectors is composed of IR & UV sensors, Combination of multiple IR & UR sensor or Standalone sensors depending on as to the flame detectors configuration.
Whenever the fire breaks out, It Emits Energy & Radiations from burning hydrocarbon-based objects in the form of UV & IR emissions Unique fire radiation is also emitted, this radiation is detected by UV/IR sensors & analysed for unique. The radiation pattern of fire. Once it is identified. It is verified multiple times in a few seconds to verify the existence of a true flame. Once confirmed alarm is generated.
For More Information click the below-given link :
https://www.youtube.com/watch?v=9XvTGk94RWU
Flame Detectors for oil and gas?
The risk of fire breaking out in oil & gas application is very high as the application make use of highly flammable fuel & liquid chemical (i.e. oil) , Flammable gasses that can catch fire immediately in a fraction of second. The high-risk area can be loading, unloading of fuel & gas, a process like refining, purifying gas filling station. Which a leakage gas or fuel cab catch fire. Such case flame detectors first line of define which will detect it at lower magnitude & will take preventive action.
The Flame detectors configurations UV, IR MSIR, MSIR-UV
1. UV Strictly for indoor application & Quick Detection ideal for a storage facility or offices, clean room, laboratories,
2.IR monitoring of machinery close or inside. Heavy machinery equipment, inside the control panel, powder coating, turbine. Automotive & Petrochemical application used where the application is compact & close monitoring of static objects.
UV/IR Indoor/Outdoor General purpose application:
1. MSIR-To cover a large area ranged application: when Detection distance is very high/long indoor/ outdoor application like aircraft hangars
2.MSIR-UV: For Application with potential false alarm sources, extreme high-risk area, Fast & accurate Detection of the hazardous location.
Frequently Asked Questions to us by our Clients/Potential Customers/User
Q. How Flame Detectors used on a ship.?
Flame Detectors can be used in onshore & offshore applications .it can be used on ships where natural gas & oil are extracted from the sea. Where gasses & oils are Flammable & the risk of fire is high, .it can be mounted throughout between points of the extraction process to a storage facility.
It also can be used in transportation or commercial ships at a point, where loading & unloading of containers is done & also when it is stored to keep storage safe. It is also used in generator rooms, Electrical rooms on a ship for monitoring safety purposes.
Q. How to Clean Flame Detectors?
Flame Detectors' front glass must be kept clean all the time contamination (dust, Fogg, oil, ice, etc.)on its window can reduce its ability of detection, lowering its overall performance. Hence, glass must be regularly cleaned with a soft cotton or a piece of clean cloth. For stains that are harder to remove, isopropyl alcohol can be used.
Q. How to test Flame Detectors?
1. The non-hazardous area / safe zone flame detector can be tested with a standard square fit pan filled with a hydrocarbon-based fuel. (I.e. N-heptane, Diesel, kerosene, etc.), kept 25 m away from detector Lit. When the fire is exposed, the flame detector should detect it in less than 10 seconds.
2. For hazardous area:
Flame Detectors can be tested with a test lamp. (FTU-33133-FLP).from a distance of 5 meters. It is a safe testing method without actually generating a fire. The Test Lamp Emits the equivalent Radiation of those generated by an actual fire. Flame detectors should detect in less than 10 seconds.
3. For general testing:
Expose lighter flame to Flame Detectors (keeping notch on Maximum Flame)From a distance of 1 to 2 meters. Flame detectors should detect in less than 5 seconds.
Flame Detector for oil and gas:
The risk of fire breaking out in oil & gas application is very high as the application make use of highly flammable fuel & liquid chemical (i.e. oil) , Flammable gasses that can catch fire immediately in a fraction of second. The high-risk area can be loading, unloading of fuel & gas, a process like refining, purifying gas filling station. Which a leakage gas or fuel cab catch fire. In Such case flame detectors, first line of define which will detect it at lower magnitude & will take preventive action.
The Flame detectors configurations UV, IR MSIR, MSIR-UV
1.UV Strictly for indoor application & Quick Detection ideal for a storage facility or offices, clean room, laboratories,
2.IR monitoring of machinery close or inside. Heavy machinery equipment, inside the control panel, powder coating, turbine. Automotive & Petrochemical application used where the application is compact & close monitoring of static objects.
UV/IR Indoor/Outdoor General purpose application:
1. MSIR-To cover a large area ranged application: when Detection distance is very high/long indoor/ outdoor application like aircraft hangars
2. MSIR-UV: For Application with potential false alarm sources, extreme high-risk area, Fast & accurate Detection of hazardous location.
WRITTEN BY
Ambetronics Engineers Pvt Ltd
Manufacturer of Gas Detector, Gas Leak Detector, Gas Detection System Portable Gas Detector, and Flame Detector | Web Factory | Industrial Automation
0 notes
Link
“FIRE” – The most feared industrial hazard! are caused by chemical, mechanical, civil, electrical, or other process failures due to accident, negligence or incompetence. Protection ensures that a minor event & a small containable fire does not turn into a catastrophic event that can devastate a business, the lives of workers and a community. But these catastrophic fires can be prevented by simply installing continuous flame monitoring equipment. Hence, to avoid such hazards, Flame Detector is the most suitable solution as it responds immediately because Flame Detectors are optical devices, that can respond to flames in less than a second. Don't let a minor flame turn into a catastrophic fire. Detect one within seconds with Ambetronics range of Flame Detectors.
0 notes
Link
Our Portable Gas Detectors can detect the smallest leak of Oxygen, Toxic, Combustible or VOC type gases with the display of gas concentrations on the LCD display. These detectors have the feature of easy handling and programming with 3 keys and power supply with rechargeable batteries and on/off option. They have a password-protected function menu, plug-in sensor, and built-in audio buzzer. These Portable Gas Detectors also have an optional data logging facility with 50,000 records which are visible in ASCII format while downloading to PC via USB interface.
0 notes
Link
Whether it’s a stove, grill, fryer or any other cooking equipment, LPG and PNG leaks present a constant flammable risk to the workers as well as to the property. In order to have optimum protection against LPG explosions and mishaps, installing an LPG gas detector of best industrial-grade is very crucial. However, with so many choices available today, it’s undoubtedly challenging to pick one that’s perfect for your needs. We are a pioneering company in the manufacturing of LPG leak detectors that are PESO, CE, CMRI certified. Our LPG Gas Detectors consists of powerful gas sensors that are capable of detecting even the smallest leak.
0 notes
Link
In Pharmaceutical industries, controlled storage and transit conditions are important aspects of the quality assurance system. The temperature variations in Pharmaceutical warehouses, have adverse effects on the efficiency and shelf life of medicinal raw materials and products. Hence in the pharmaceutical industries, continuous monitoring, recording, and reporting of temperature excursions are important. As a leader in Refrigeration Monitoring in cold storage and transportation markets, some of the high-value companies trust & rely on us for complete end-to-end solutions in Cold Chain monitoring systems. We provide both Wired and Wireless tracking & monitoring systems.
0 notes
Photo
Webinar Alert
Currently, many companies in every industry are searching for new digital business models. But can this be done without major intervention in the machine or plant?
Yes, it can be. With mbEDGE.
We have come up with yet another webinar on - "The IIoT solution for your digital transformation"
In this webinar we will show you how you can make your machine IIoT-compatible with little investment
Join us on Thursday May 28, 2020 at 1:30 PM IST
Registration link: https://zoom.us/webinar/register/WN_y-DIh8-9RqOV9oBZcJyenA
Who should attend?
- Automation Engineers
- IT Specialists
- Manufacturers
- And all who have keen interest in industrial automation
Use this webinar as an introduction to the digitization of your systems.
#automation hashtag#iiot hashtag#iot hashtag#electricalengineering hashtag#engineers hashtag#electricalengineer hashtag#digitaltransformation
0 notes
Text
Importance of Gas Leak Detection System| PESO Certified | LPG Gas Detector | Manufacturer in India
Going to your favorite restaurant/hotel for a date, party with friends, or a family dinner — sounds good, but what if the place that you are hanging out is not Fire Compliant, as most of the hotels are always dotted with fire hazards at every corner. They have parking spaces, cooking oils, electrical connections, and paper products. One small spark and can turn a great night into a disaster. Fire will not only cause material damage but will cost lives, just because the owner of the restaurant was not aware of the hazards or didn’t care about safety.

“Safety isn’t expensive, it’s Priceless — Unkown”
Our Mission at Ambetronics Engineers Pvt Ltd is to provide the best quality and the optimum solution that is needed for the Human and Industrial Saftey. We are the largest manufacturer of Gas Detectors, Gas Analyzers, Flame Detectors, Data Loggers, Cold Chain, Clean Room, Industrial Automation & Internet of Things(IoT).
According to the National Fire Protection Association, more than 8257 eateries report an annual fire in the USA alone, the USA being so strict in regulations & rules, still, they restaurants claim more than $259 million. Therefore, it is a mandatory requirement to measure Combustible and Toxic Gas Hazards. Liquified Petroleum Gas(LPG) and Piped Natural Gas(PNG) have a constant risk to the chefs, managers, servers & the staff. Talking about India, 87% of the restaurants/eateries do not comply with the fire standards & regulations.
0 notes
Photo

The GT-4220-FLP-S type of PNG/LPG Gas Leakage Detectors are Ambetronics’ one of the latest application-based customized products, upgraded from the previous conventional type of PNG/LPG Gas detectors. With Government’s Safety Norms getting strict day-by-day for fire hazards in kitchen areas of Hotels, Restaurants, cafeterias, Industrial & Commercial Canteens and in multi-storey residential premises; Ambetronics offer the best solutions about taking safety measures for detecting LPG/PNG/combustible gases far before they turn into major fire hazards.
These micro controller based GT-4220-FLP-S units are available in PESO / CCOE tested flameproof enclosures and widely used as PNG or LPG gas detectors in applications such as commercial kitchens, industrial kitchens, LPG/PNG/CNG bullet yards/storage yards, Gas Banks, etc.
#LPG PNG Gas detector#LPG CNG Gas detection companies in mumbai#LPG Gas detector price#LPG gas Leakage detection System#CNG gas leak detector
0 notes
Photo

The GT-2511-series Smart Gas Detector is a microprocessor based detector broadly used as combustible gas detector or toxic gas detector and can be customized as per the requirement of gases used on site. It comes with an easy-to-read LCD and provides fast and reliable output. This gas Transmitter ensures digital LCD display of gas concentration and has sensor check provision.
These Gas detectors have non-intrusive programming for flameproof model using magnetic pen and has password protected programming with password changing facility. They are available in weatherproof and CMRI tested flameproof enclosures.
0 notes
Photo

On this auspicious occasion of Mahavir Jayanti, we send you and your family the best of the wishes. May you be blessed with the strength to follow the right path of ahimsa and goodness. Happy Mahavir Jayanti | Jai Jinendra
0 notes