Tumgik
#RCBO Residual Circuit Breaker
mebaelectric · 6 months
Text
RCBO Ensures Electrical Safety in Your Home
A sophisticated electrical safety device, RCBO Residual Circuit Breaker, guards against fault currents as well as overcurrents by keeping an eye on the current flowing through a circuit. It accomplishes this by spotting electrical current imbalances and quickly cutting the circuit when a problem is found, greatly lowering the possibility of electric shock and fire.
Tumblr media
How Do RCBOs Operate?
Finding Residual Current: The live (phase) and neutral wire balance of a circuit is continually monitored by the RCBO. An appliance's input current and output current are equal in a healthy circuit. An imbalance results when a human unintentionally touches a live component because part of the current passes through it and down to the ground, lowering the returning current. This imbalance is frequently detected by the RCBO in milliseconds, at which point it trips, turning off the electrical supply and averting major harm or death.
Protection against Overcurrent: Short circuits and overloads can result in overcurrent. To reduce the risk of fire dangers and potential damage to appliances and wiring, the RCBO recognizes these situations and disconnects the circuit. The RCCB Circuit Breaker is also vital.
Why Do RCBOs Matter?
Safety: An RCBO's main function is to offer a high degree of protection against the possibility of fire and electric shock. It guarantees occupant safety by identifying fault currents and overloads.
Cost-effectiveness and Convenience: By combining the functions of an MCB with an RCD, RCBOs save installation costs and the requirement for separate devices, freeing up space in the consumer unit (fuse box).
Compliance: To fulfill electrical safety requirements, several areas have legislation requiring the installation of RCBOs in new construction and during significant modifications.
Tumblr media
Establishment and Upkeep
Even though RCBOs are sturdy and dependable, a trained electrician should always perform their installation and maintenance. When an RCBO from RCBO Circuit Breaker Manufacturer is installed correctly, it is guaranteed to be appropriately rated for the circuit it guards, improving safety and adhering to regional electrical codes. As advised by the manufacturer, routine inspections and testing are essential to preserving their protective qualities over time.
1 note · View note
mcdelectrics · 2 months
Text
Why You Need a Professional Electrical Contractor in Melbourne for New Home?
Building a new home is an exciting venture, but it requires meticulous planning, especially when it comes to electrical installations and one must engage qualified and professional electrical contractor in Melbourne for the same. Professional electrical contractors play a crucial role in ensuring that your new home is equipped with safe, efficient, and up-to-date electrical systems. Electricians dothe installation of comprehensive wiring solutions like setting up state-of-the-art lighting fixtures, air conditioning, CCTV, alarms, home automation devices, solar power and many more services.
In addition to new home installations, a professional electrician in Beaconsfield offers maintenance services and specialises in enhancing the overall lighting of houses with modern and energy-efficient lighting. Garden lighting is becoming important nowadays as it adds significant charm and appeal to the look of the house. Nowadays, most people are choosing LED lights for lighting up the interiors as not just the light quality is good but also the power consumed is far less than other types of LED lights.
Tumblr media
A Quick Brief About Various Services Offered by Leading Electricians
Switchboard Upgrade:The switchboard is the central hub that distributes electricity throughout the home and hence it must be of good quality for safety. Upgrading to a modern switchboard with RCBO protection enhances safety by combining the functions of a circuit breaker and a residual current device. Professional electricians provide a certificate of compliance, that shows all work meets the stringent safety standards and regulations.
AC Installation Services: Installation of AC, must be done by specialists who have years of experience as this appliance is quite sophisticated and needs proper installation. One must not keep the AC not serviced for a long time as this will make the air inside the house polluted which is not at all good for the health of individuals.Professional electricians manage everything from installing split system air conditioning units to offering repair and maintenance services. Regular servicing enhances the efficiency and longevity of split AC units, ensuring better indoor air quality.
When it comes to electrical services the leading contractors have a huge portfolio of successfully completed work and genuine client testimonials that is the proof of work done by them. Check the portfolio and connect with the leading electricians to get your various electrical work done successfully without any issues.
Source: https://emergencyelectricianmelbourne.blogspot.com/2024/08/why-you-need-professional-electrical.html
0 notes
shubh12 · 4 months
Text
0 notes
lnt-suffin · 6 months
Text
Empower Your Electrical System: MCB, RCCB, and Electric Panel Boards
Circuit breakers are basically safety devices for anything that uses electricity. These fixtures, which are made of reusable and high-temperature resistant material, guard the dangerous electrical circuit ends. MCB, MCCB, RCCB, RCCD, and RCBO are all types of circuit breakers for electricity systems. They are used in homes to protect people against hazards and appliance damage. 
Tumblr media
Let’s understand the importance and uses of different circuit breakers in electricals.
Different Circuit Breakers of Electricals
The design of the devices involves performing specific functions. MCB and RCCB are used for small-sized devices with a small current that is not more than 125 amps. MCCBs are used for high currents up to 100 amps.
Safety and efficiency are the most important aspects. Three essential components play an important role in achieving this:
Miniature Circuit Breaker (MCB)
Residual Current Circuit Breaker (RCCB) 
Electric Panel Board 
Being able to understand and give attention to the key elements of these circuit breakers is of extreme importance for households, offices and industries in ensuring a safe, functional and secure environment. 
Miniature Circuit Breakers (MCB)
MCBs, or Miniature Circuit Breakers, serve as automatic switches that interrupt the flow of electricity in case of overcurrent or short circuit conditions. This feature reduces the chance of damaging some household appliances such as electric irons, wiring, and fires. MCBs are electromechanical devices that are fundamental for the safety of electrical circuits. Their main function is to protect electrical circuits, appliances, and wiring from damage and fire hazards. 
Importance and Uses 
Overcurrent Protection: The MCBs detect a high current flow, which trips down the power supply, thereby preventing electrical appliances from overheating.
Short Circuit Protection: In the cases of a short circuit, MCB manages to cut off the broken part of the circuit, so fires that electrical devices create are difficult to occur.
Tripping Mechanism: MCB has thermal or electromagnetism for the detection of abnormal currents and trip accordingly.
Resettable: Rather than depending on the concept of manual reset, unlike fuses, MCB can be easily reset manually after tripping, therefore leaving the protection on.
Residual Current Circuit Breakers (RCCB)
RCCBs, also called residual current devices, are meant to offer electrical safety. Although MCB works to watch out for overcurrent and short circuits, the RCCB performs a specific function, identifying leakage currents, especially the ones caused by electric shocks.
Importance and Uses
Leakage Current Detection: RCCB  always ensures a steady supply because they continually monitor the imbalance of currents flowing in and going out. Leakage of the current is detected immediately. They react within a second on the detection of a fault, disconnecting the circuit from the inside to the outside.
Protection Against Electric Shock: RCCB cut off power at the speed of seconds after getting to know electric current leakage. They minimise the risk of electrocution and protect people from being exposed to an accident.
Sensitive Operation: RCCB operates with high sensitivity. They ensure that even the smallest leakages are detected, even as low as a few milliamperes.
Electric Panel Boards
Electrical panel boards (also known as circuit breaker panels, distribution boards, or load centres) are the power distribution sources for all the electrical components in a building. They serve as a central hub for distributing electricity throughout a building or facility. It houses protective devices such as MCBs and RCCBs and facilitates organised and safe electrical distribution by distributing power from the main supply to various circuits within the building. 
Importance and Uses
Circuit Distribution: The electric panels boards are usually installed near the main electricity distribution systems, and they are designed to distribute electrical power coming from the main panel to different circuits within a building so as to ensure both balanced and efficient power distribution.
Protection Devices Integration: Most MCB/RCCB are generally found within electric panel boards, which act as a common source of protection from overcurrents, short circuits, and electric shocks.
Organization and Accessibility: The electrical Panel board facilitates the organisation of electrical current, which makes it easier to find and take care of the individual circuits. Moreover, they allow maintenance actions to be performed and provide easy access in case of maintenance and troubleshooting.
Conclusion
It is important to understand the role and functions of MCB, RCCB, and Electric Panel Boards in order to avoid electrical hazards and to ensure the proper functioning of the electrical system. Whereas MCB eliminates overcurrent and short circuits, RCCB is installed to detect leakage current that would cause electric shocks. 
Such electrical supplies must be well-stocked and from LnTSufin to meet your electrical system requirements.
0 notes
gripelectric24 · 6 months
Text
0 notes
p-a-s · 6 months
Text
Tumblr media Tumblr media Tumblr media Tumblr media Tumblr media
Exploring the Benefits of RCBO: Safety First in Electrical Systems
Hey, electrical enthusiasts! Let's dive into the world of Residual Current Circuit Breaker with Overcurrent Protection (RCBO). 🛠⚡ RCBOs are an essential component in electrical systems, combining the functions of a residual current device (RCD) and a miniature circuit breaker (MCB) into one unit. Here's why they're a game-changer: Enhanced Safety: RCBOs offer dual protection against both earth faults (residual current) and overcurrents. This means they can detect even tiny leakage currents, minimizing the risk of electric shocks and fires due to faults in the system. Individual Circuit Protection: Unlike traditional circuit breakers that protect entire circuits, RCBOs provide protection on a per-circuit basis. This targeted approach allows for quicker identification and isolation of faults, reducing downtime and increasing overall safety. Flexibility and Efficiency: With RCBOs, you have the flexibility to protect specific circuits or appliances without affecting the entire system. This targeted protection optimizes the efficiency of electrical installations, ensuring reliable operation while minimizing the risk of nuisance tripping. Compliance and Standards: As electrical safety regulations become more stringent, RCBOs offer compliance with the latest standards and codes. They provide peace of mind knowing that your electrical system meets the necessary safety requirements. Ease of Installation and Maintenance: Installing RCBOs is straightforward, and their modular design simplifies maintenance and upgrades. This means reduced installation time and costs, as well as easier troubleshooting and servicing in the future. Whether you're upgrading an existing electrical system or planning a new installation, consider incorporating RCBOs for comprehensive protection and peace of mind. Have you experienced the benefits of RCBOs firsthand? Share your thoughts and experiences in the comments below! 🔌🔒
CSQ Electric: https://csqelectric.com/
1 note · View note
Text
How does short circuit protection work?
People have electrical circuits in their home that provides electric current to the charged particles like generators, batteries, etc. A short circuit happens when electricity finds a shorter, unintended path to flow through instead of following the designated wires. This can allow excessive current flow through the circuit causing multiple problems, such as;
This sudden change creates several problems:
Too much electricity
Heat and sparks
Tripped breakers
In simple words, a short circuit can cause various problems like overheating, sparks, and even fires. So, it is crucial to know the cause of short circuits which can be a faulty wire or damaged appliances. Also, take necessary steps to guard them to prevent fire. In such conditions, you will require a short circuit protection device to protect your electric devices from overcurrent.    
Why are circuit protective devices important?
Short circuit protection devices play a crucial role in protecting electrical systems. They prevent high fault currents from flowing during electrical faults that not only safeguard the installation but also prevent harm to consumers. Circuit breakers or fuses offer overcurrent protection by automatically disconnecting the supply when there's an overload or fault current. As we discussed above, overloads happen when there's a faulty item or too many devices connected to a circuit. On the other hand, short circuits occur when a live wire touches an exposed part or another wire with low resistance. It happens often due to wiring errors or cable damage. Similarly, Earth faults occur when a live wire touches an earthed conductor or exposed part, though, they do not involve high current flow.
Therefore, you must have an appropriate circuit protection, installed to ensure your safety.
What are the different types of circuit protection?
A fuse is a safety device that contains a piece of wire that melts easily. If the current passing through the fuse becomes too high, the wire heats up until it melts, breaking the circuit. It stops the current flow immediately.
There are different types of fuses available:
●      BS3036 rewirable fuses:
These are commonly found in domestic circuits. They are affordable, easy to repair, and simple to check. However, there are chances of their misuse by an incorrect fuse wire making them too hot.
●      BS1361/1362 cartridge fuses:  
These are used in plug tops and distributions. Cartridge fuses are relatively accurate as they have a low fusing factor, and are easy to replace. However, they are more expensive than reusable fuses.
●      BS 88 High Breaking Capacity Fuses (HBC):
Normally, people use them in industrial setups and motor circuits. You can operate & replace them easily. However, they are costly to replace due to not having external arcing.
Residual Current Devices (RCDs) can detect and disconnect the power supply in case of an earth fault. For example, when a live wire touches an earthed equipment case or when a live wire is cut. These faults can lead to electric shocks and fires, so RCDs are crucial safety devices.
A Miniature Circuit Breaker (MCB) is another safety device that protects electric circuits from overcurrent. Unlike fuses, MCBs are reusable and easier to use. Since they have an on/off switch for circuit isolation, they are safer because the conductor is enclosed within a plastic casing. However, they are more expensive than fuses requiring regular testing.
Circuit breakers act as switches and open when there's excessive current flow. Professionals can reset them without damage in case of overheating. MCBs alone don't protect against electric shocks caused by earth leakage. Short circuit protection device manufacturers suggest using Residual Current Devices (RCDs) and Residual Current breaks with Overcurrent (RCBOs). The combination of the three can protect against overcurrents and earth leakage current faults.
0 notes
shreelight · 8 months
Text
Tumblr media
Elevate your electrical safety game with Schneider RCBOs! Shreelight Power Pvt. Ltd. in Vadodara introduces cutting-edge Residual Current Circuit Breaker with Overcurrent Protection (RCBO) solutions. Experience the perfect blend of safety and performance. Upgrade your circuits with Schneider.
0 notes
ismailkar · 9 months
Text
Den 4-poligen FI/LS-Schalter vom Typ B verstehen eine umfassende Anleitung
In the realm of electrical systems, safety is paramount. One crucial component that plays a vital role in ensuring the safety of electrical installations is the Residual Current Circuit Breaker with Overload Protection (RCBO), commonly referred to as an FI/LS switch. Among the various types available, the 4-pole Type B FI/LS switch stands out for its versatility and enhanced protective capabilities.
What is a 4-Pole Type B FI/LS Switch?:-
A 4-pole Type B FI/LS switch is a specialized circuit protection device designed to safeguard electrical installations against two main threats: earth leakage currents and overloads. Let's break down its key features and functionalities:-
Four Poles:- The "4-pole" designation indicates that the switch consists of four main conductive paths. Each pole serves a specific purpose, and together they provide comprehensive protection against various electrical faults.
Type B Characteristics:- The "Type B" classification refers to the sensitivity of the switch to different fault currents. Type B is particularly effective in detecting and responding to sinusoidal and pulsating direct currents, making it suitable for a wide range of applications where diverse loads and equipment may be present.
FI Functionality:- The FI (Fault Interrupter) function is integral to the device's ability to detect and respond to earth leakage currents. Any disparity between the current flowing into and out of the installation is quickly identified, triggering a trip to isolate the circuit and prevent potential electric shocks.
LS Protection:- The LS (Overload Protection) feature ensures that the circuit is safeguarded against excessive current loads. This can occur due to various reasons, such as short circuits, and the LS function acts as a circuit breaker to interrupt the current flow and prevent damage to the equipment.
Applications of 4-Pole Type B FI/LS Switch:-
The versatility of the 4-pole Type B FI/LS switch makes it suitable for a wide range of applications, including:-
Residential Installations:- Protecting homes from electrical faults is a primary application of the 4-pole Type B FI/LS switch. It ensures the safety of residents by promptly isolating faulty circuits.
Commercial and Industrial Settings:- In commercial and industrial environments, where diverse loads and equipment are common, the Type B FI/LS switch provides robust protection against both earth leakage currents and overloads.
Renewable Energy Installations:- With the increasing adoption of renewable energy sources, the 4-pole Type B FI/LS switch plays a crucial role in protecting solar and wind power installations from electrical faults.
The 4-pole Type B FI/LS switch is a sophisticated and versatile device that combines fault detection, circuit interruption, and overload protection. Its ability to address diverse electrical challenges makes it a key component in ensuring the safety and reliability of electrical systems across various sectors. As technology continues to evolve, the demand for advanced circuit protection devices like the 4-pole Type B FI/LS switch is expected to rise, contributing to the ongoing enhancement of electrical safety standards.
FÜR MEHR INFORMATIONEN:-
fi/ls schalter 4-polig typ b
0 notes
wenzhou-cht-electric · 9 months
Text
Tumblr media
RCBOs - Residual Current Circuit Breaker with Overcurrent Protection
CHT Electric offers RCBOs with 6kA breaking capacity at reasonable prices worldwide. RCBOs are used for overload protection, short-circuit protection, and protection against alternating earth fault currents. It is used in all residential, industrial, and many more places. It is an Electromagnetic type, voltage-independent, and rated voltage to 230V, Circuit. It is made up of top-quality metal and plastic materials. For more details call us at +86-15858819087.
0 notes
meotonghop · 1 year
Text
RCBO và RCCB - Lựa chọn thông minh cho hệ thống điện an toàn
Trong hệ thống điện hiện đại, việc bảo vệ an toàn luôn đặt lên hàng đầu. Việc chọn lựa các thiết bị bảo vệ điện thích hợp đóng vai trò quan trọng trong việc đảm bảo rằng hệ thống điện của bạn hoạt động một cách an toàn và ổn định. Trong bài viết này, IEK SEA sẽ giúp bạn khám phá hai thiết bị bảo vệ điện phổ biến: RCBO (Residual Current Circuit Breaker with Overcurrent Protection) và RCCB…
Tumblr media
View On WordPress
0 notes
Text
Residual Current Circuit Breaker Suppliers RCCB Online | Buy ELCB Online – Micronova Group
Micronova group was established in the year 1983 with a vision to bring the latest Electrical, RF, and Microwave technologies from around the globe to Indian industries. Although the company originally started as a sourcing and distribution company, we created strong and trusted relationships with our customers and principals that enabled us to expand and diversify our business.
Miniature Circuit Breaker Suppliers in Bangalore. MCBs with breaking capacities up to 4,5 kA (S230/240, S940, etc.). We have MCBs up to 10 kA breaking capacity for domestic and commercial installations (S190, S200, S250/260/270, S440, S950/970, etc.). We also have MCBs for commercial and industrial applications with high breaking capacities and special features or accessories (S280/290, S500, S610, S220, S700, etc.). You can also get accessories for MCBs like - Auxiliary Contacts, Single Contacts, Shunt trip, under-voltage release, door lock, rotary handle with door coupling, motor 
drive. Also find MCBs which are the best according to industry standards. Get them delivered to you or buy MCBs online, buy ELCB RCBO at a reasonable price. Buy Industry Trusted brand ABB MCBs from a reliable distributor in Bangalore. 
 Buy MCB online, Residual Current Circuit Breaker suppliers which are one of the best according to industry standards. Get them delivered to you at a reasonable price in your preferred location. Buy best in class branded ABB MCBs from a reliable distributor in Bangalore.
Micronova is a leading provider and distributor of electrical, RF, and microwave technologies from around the globe to the Indian market. We provide MCB, RCCB online, power supply, buy RCCB ELCB, ELCB online ,RCCB, pluggable interface relay and other latest electrical accessories.
 Get RCCB (Residual Current Circuit Breakers) products online with best  Price List & buy ELCB and ABB RCBO products at Best Price on https://shop.micronovaimpex.com/. We are Online Suppliers, Distributors, Wholesalers, Dealers & Retailers. 
1 note · View note
Link
Get RCCB (Residual Current Circuit Breakers) products online with best  Price List & buy ELCB and ABB RCBO products at Best Price on https://shop.micronovaimpex.com/. We are Online Suppliers, Distributors, Wholesalers, Dealers & Retailers.
1 note · View note
thietbidienbeeteco1 · 2 years
Text
Aptomat chống giật là gì ? Có nên dùng aptomat chống giật ?
Tumblr media
 Hệ thống điện ở bất kỳ đâu thì cũng cần Aptomat chống giật . This is a well as very need in the power. Aptomat chống giật có nhiều loại, nhiều thương hiệu sản xuất và nhiều công suất, số pha, số cực… 
1. Aptomat chống giật là gì?
RCBO (Residual Current Circuit Overcurrent) chính là aptomat chống dòng giật với chức năng chính được sử dụng để ngắt dòng khi phát hiện có dòng chảy và sự cố về thiết bị. Aptomat chống giật là một thiết bị đóng cắt không thể thiếu ở bất kỳ hệ thống điện nào, vì nó giúp kiểm tra, rà soát các dòng điện quá tải hoặc ngắn mạch, hoặc rỉ điện, qua đó đưa ra quyết định đóng ngắt dòng điện hợp lý, dòng điện bảo vệ an toàn, chống cháy nổ khi sử dụng điện. 
2. Có mấy loại aptomat chống giật? 
một. Có mấy loại aptomat chống giật 
Aptomat chống giật được chia ra các loại cơ bản sau đây.
Cầu dao tự động chống giật dạng tép RCCB (Residual Current Circuit Breaker). 
Aptomat chống giật khối dạng có bảo vệ quá tải ELCB (Earth Leakage Circuit Breaker).
Aptomat chống giật dạng tép có bảo vệ quá tải RCBO (Ngắt mạch dư với bảo vệ quá dòng).
b. Aptomat select chống giật 
Nên chọn Aptomat ưu tiên chống giật có chức năng bảo vệ quá tải (RCBO, ELCB) thay thế aptomat thường. 
Đối với Aptomat chỉ có chức năng chống giật (RCCB) bắt buộc phải lắp MCB.
Select Aptomat chống giật theo số pha / số cực
Lựa chọn Aptomat chống giật 3 pha (3 cực) lắp cho hệ thống 3 pha tải hợp (tải 1 pha, 3 pha, sử dụng trung tính) vì sẽ khiến Aptomat chống giật bị nhảy.
3. Chức năng của Aptomat chống giật:
RCBO được kết hợp giữa RCCB và MCB trong điện thiết bị. RCBO thường được sử dụng với dòng điện định mức là 30mA. Aptomat chống giật FUJI có một vô số trò chơi cùng quan trọng đó là được sử dụng để ngắt điện khi gặp sự cố về đường thẳng hoặc là điện áp quá tải, nhằm mục đích phục hồi trạng thái bị tắt điện.
Aptomat chống giật 1 pha: nó so sánh dòng điện chạy qua 2 dây mát và lửa, nếu dòng điện này khác nhau quá một ngưỡng rò nhất định thì nó sẽ ngắt điện khỏi tải, không cho tải làm việc nữa.
Aptomat chống giật 3 pha: nó so sánh dòng điện chạy qua 3 dây pha và dây trung tính, nếu dòng điện này khác nhau quá một ngưỡng rò nhất định thì nó ngắt.
4. Cấu tạo Aptomat chống giật RCBO và nguyên lý hoạt động:
Buồng dập hồ quang: Buồng có thiết kế những tấm kim loại ghép lại với nhau. Những khoảng trống giữa các tấm kim loại có tác dụng chia nhỏ lượng hồ quang ra để dập và giảm lượng nhiệt sinh ra. 
Thermal Overload detection: Bộ phận phát hiện ra sự quá tải nhiệt.
Manual switch: Thao tác đóng/ mở
RCD test button: Nút kiểm tra RCD.
Short circuit detection coil: Cuộn dây phát hiện ngắn mạch.
RCD toroid – RCD hình xuyến: Bộ phận nhạy cảm của dòng rò bên trong RCD. Bộ phận này kết hợp với một biến dòng vi sai.
ARC chute: Máng dập hồ quang.
Cấu tạo Aptomat chống giật FUJI (RCBO)
Cấu tạo Aptomat chống giật 
Tumblr media
Cấu tạo Aptomat chống giật 
Nguyên lý hoạt động
Aptomat chống giật thiết kế cho 2 dây nóng và dây nguội của dòng điện đi qua 1 cuộn cảm. Đây giống như 1 biến thế thông thường với cuộn sơ cấp 1 vòng dây (chính là 2 dây mát và lửa đi qua tâm biến thế) và cuộn thứ cấp có vài chục vòng dây.
Aptomat chống giật 1 pha:
Hai dây mát và nóng đi qua 1 biến dòng có lõi sắt hình xuyến và cuộn thứ cấp. Dòng điện sẽ đi ra ở dây nóng và về tại dây mát và ngược lại. Khi 2 dòng điện bằng nhau từ trường sẽ tự biến thiên và điện áp ra cuộn thứ cấp  = 0. Khi điện áp 2 dòng khác nhau sẽ sinh ra từ trường biến thiên khác nhau, cuộn thứ cấp xuất hiện dòng điện cảm ứng và được đưa vào IC để kiểm tra sự an toàn.
Aptomat chống giật 3 pha:
Ở Aptomat chống giật 3 pha dòng điện sẽ tuyền ra tại dây nóng và về ở dây mát và ngược lại dẫn đến dòng điện ngược chiều nhau. Từ đó, từ trường biến thiên tại lõi sắt của biến dòng có chiều ngược nhau. Khi 2 dòng điện có giá trị bằng nhau thì từ trường biến thiên sẽ tự diệt lẫn nhau khiến điện áp ra cuộn thứ cấp của biến dòng = 0. Khi  2 dòng điện có giá trị khác nhau thì từ trường cũng sẽ khác nhau khiến dòng điện cảm ứng xuất hiện trên cuộn thứ cấp biến dòng. Sau đó được đưa vào IC để kiểm tra.
5. Các thông số kỹ thuật của Aptomat chống giật
In: Đây là ký hiệu định mức.
Dòng rò: Aptomat chống giật thường sẽ được chế tạo dòng rò cố định ở mức 15mA, 30mA hoặc dòng có thể điều chỉnh lên đến các mức như 100mA/ 200mA/ 300mA/ 500mA (có lẫy gạt để có thể chọn được mức dòng rò tương ứng). Khi dòng điện rò bị vượt quá dòng quy định, lúc này aptomat chống giật sẽ tự động ngắt.
Ue: Điện áp làm việc định mức của aptomat chống giật.
Icu: Dòng cắt ngắn mạch là khả năng chịu đựng được của dòng lớn nhất của tiếp điểm trong 1 giây.
Icw: Khả năng chịu dòng ngắn mạch trong 1 đơn vị thời gian của thiết bị.
Lcs: Khả năng cắt thực tế khi xảy ra sự của của thiết bị. 
AT: Dòng điện tác động.
AF: Dòng điện khung.
Mechanical/electrical endurace: Số lần đóng ngắt bằng tay cho phép/số lần đóng cắt điện cho phép của thiết bị.
6. Đặc điểm hình dáng Aptomat chống giật
Tumblr media
Về thông số kỹ thuật chung
In: Dòng điện định mức.
Ue: Điện áp làm việc định mức.
Icu: Khả năng chịu đựng dòng điện lớn nhất của tiếp điểm trong 1 giây.
Icw: Khả năng chịu được dòng ngắn mạch trong 1 đơn vị thời gian.
Ics: Khả năng cắt thực tế của thiết bị khi xảy ra sự cố..
AT: Dòng điện tác động.
AF: Dòng điện khung (Ampe Frame)
Về đặc điểm hình dáng
Nhìn chung Aptomat chống giật có hình dáng và kích thước tương đương với Aptomat thông thường.
Aptomat chống giật có công tắc điện ON-OFF và 1 nút TEST có công dụng để người dùng có thể kiểm tra tình trạng hoạt động của Aptomat.
7. Hướng dẫn chọn Aptomat chống giật 
Lúc lựa chọn Aptomat chống giật, người dùng cần lưu ý một vài vấn đề sau để tránh chọn sai  không thể sử dụng được:
Chọn loại aptomat: Aptomat chống giật có chức năng bảo vệ quá tải (RCBO, ELCB) có thể dùng thay thế aptomat thường nhưng vì cấu tạo phức tạp hơn nên loại này thường có dòng cắt ngắn mạch thấp. Sử dụng RCBO, ELCB sau aptomat thường sẽ bảo vệ hệ thống điện tốt hơn.
Chọn số pha / số cực: Sai lầm thường gặp nhất là khi chọn Aptomat chống giật 3 pha  lắp cho hệ thống 3 pha tải hỗn hợp dẫn tới át chống giật bị nhảy. Đối với tải 3 pha hỗn hợp phải sử dụng loại 4 pha. Đối với điện 1 pha phải sử dụng aptomat 2 pha.
Chọn dòng định mức: Đối với RCBO, ELCB chọn dòng định mức căn cứ vào công suất sử dụng tương tự như chọn aptomat thường.
Chọn dòng rò: aptomat chống giật thường có 3 loại theo dòng rò 15mA, 30mA, 100/200/500mA. Thông thường các hệ thống nhỏ, các khu vực dân dụng dùng dòng chống rò 30mA.
8. Các lưu ý khi sử dụng ?
Không lắp đặt ở nơi ẩm ướt, khi lắp aptomat chống giật cho bình nước nóng thì nên đặt ở phía bên ngoài.
Phải test trước khi dùng. Test ít nhất 1 lần /tháng để kiểm tra thiết bị còn hoạt động tốt hay không?
Khi lắp aptomat chống giật, phía trên aptomat là điện vào, phía dưới là điện áp ra tải, nếu đấu ngược sẽ hư aptomat ngay khi có dòng.
9. Nên dùng aptomat chống giật của hãng nào ? 
Aptomat chống giật là thiết bị trọng yếu trong các hệ thống điện nhưng do việc chế tạo phức tạp đã đẩy giá thành lên cao hơn vài lần so với Aptomat thường. Bởi vì vậy nên nó không được sử dụng phổ biến bằng Aptomat thường. Nhà sản xuất cũng không chế tạo nhiều mã sản phẩm đa dạng như Aptomat thường. 
10. Có nên dùng aptomat chống giật ? 
Aptomat là một thiết bị điện bảo vệ sự an toàn cho hệ thống điện của bạn. Khi lắp đặt aptomat chống giật, nếu mạch điện xuất hiện dòng rò sẽ tự động ngắt nguồn điện tại nơi phát hiện. Nó giúp tự ngắt điện khi có dòng điện rò xuống đất từ đó có thể hạn chế được các tình trạng điện giật cho mọi người, đảm bảo được tính mạng an toàn cho mọi người.
Vì thế, CB chống dòng là một sự lựa chọn hoàn hảo nhất bởi nó đóng một trò chơi rất quan trọng đối với những người lớn không gian như công ty xây dựng. Có thể kể đến những công dụng mà Aptomat mang lại như:
Nguồn bài viết:  https://beeteco.com/aptomat-chong-giat-la-gi-co-nen-dung-khong.html
0 notes
thecomponentsstore · 2 years
Text
Why is Circuit Protection Important? Panasonic Electronic Components distributors
All the appliances that we are using for heating, lighting, etc have electrical circuits. Electricity from power stations is being provided to them via various transmitters and distribution networks.
Circuit Protection is necessary because it protects you and your property in case of an electrical fault. In case, there is a short circuit or faulty wiring, there is a high risk of injury.
Tumblr media
All these electrical circuits have maximum limits for the current which in the case that exceeds their limit, causes overheating, which can cause fire to break out.
How does Circuit Protection work?
Circuit protection is basically ensured by tripping the circuit.
The supply of electricity is cut off to that distinct circuit automatically.
Cutting off electricity prevents the wire from overheating and potentially causing fire and other hazardous situations.
Circuit Protection Devices
Fuses: Fuses are the most traditional method of circuit protection. They need to be replaced whenever the fuse ‘blows’.
Miniature Circuit Breaker: MCBs or Miniature Circuit Breakers are modern Circuit Protection devices. Unlike fuses, there don’t need to be replaced after they drip down but simply turn up to restore the power.
Residual Current Devices: RCDs or Residual Current Devices stop the electrical current when identifying an abnormality in its flow. The advantage RCDs have over MCBs is that they can be used for more than one circuit.
Residual Current Breaker and Overload Protection: RCBOs or Residual Current Breaker and Overload Protection are essentially a combination of RCDs and MCBs. They offer the maximum level of circuit protection.
If you are looking for a Panasonic Electronic Components distributor, Check out our website The Components Store. We provide 100 percent unique products at affordable prices. We are a Panasonic semiconductor supplier who provides you with electronic products at the earliest. Visit our website for more information.
0 notes
binghalibeng · 2 years
Text
Capacitor bank panel supplier
Tumblr media
 A system controls and monitors various equipment and devices in an enclosed unit. The electrical panel is one of the integral parts of industrial electrification. Capacitor bank panel supplier They regulate the electrical functioning of machinery and equipment present in the factory. Electrical panels are necessary because they protect the machinery from being damaged due to electrical failures and overloading. which is the leading manufacturer and supplier of low voltage and high voltage control panels in India, produces the best and efficient products. Since there are different types of panels available in different sizes and strengths; you must first refer to the catalogues to choose as per your requirement. However, the most important is to look for suitable electrical additions that are used for different buildings and industries. Enclosed distribution panels are more protective and provide better security to all of the machinery, and other electrical equipment present. Electrical Panel is a component of an electricity supply system that divides an electrical power feed into subsidiary circuits while providing a protective fuse or circuit breaker for each circuit in a common enclosure. Normally, a main switch, and in recent boards, one or more residual-current devices (RCDs) or residual current breakers with over current protection (RCBOs) are also incorporated.
0 notes