#Oracle Database Appliance X4-2
Explore tagged Tumblr posts
cdicdd · 8 years ago
Text
Ingénieur Système
Dans le cadre de renforcer notre équipe architecture technique, nous recrutons un Ingénieur Système Confirmé
Recrutement Ingénieur Système Confirmé
Dans le cadre de renforcer notre équipe architecture technique, nous recrutons un Ingénieur Système Confirmé ayant une expérience de 5 ans minimum.
Compétences clés: • Linux RHEL/Oracle, AIX, Oracle Database Appliance X4-2/X5-2, Windows Server 2008/2012 • Oracle Weblogic 10g/11g/12c • Oracle Forms/Report 11g/12c • Suite BDOC • SAP BO, QlikView • OpenLDAP •…
View On WordPress
0 notes
lanblog729 · 4 years ago
Text
Mixmeister Update Catalina
I want an LED indicator that will lite when an AC circuit is on. The line/output is 24vAC at.5A. This is an irrigation controller, which sends 24vAC to activate a water/sprinkler controller valve. I need a basic cicuit design and/or instruction. NKK Indicators feature LED illumination and are a complement to each Series switch. A wide array of colors and mounting options are available. Nov 10, 2019 3# Simple LED AC power indicator circuit. This is an LED Indicator for remote AC loads Circuit. At very cheap and use electronic parts a little. This circuit uses diode rectifier cheapness, Resistor and LED only. As a result, assemble the circuit shows flowing from AC current Source in load easily. The LED blinks at a 10 percent duty cycle (0.1 second on, 2.9 seconds off), that is, the light is on for a very short period of time. Slow blink – The startup sequence has been initiated on the host. The LED blinks at a 50 percent duty cycle, which is noticeably longer than the STANDBY BLINK. For best results, the LED color should be the same as the lens color. If the bulb is behind a clear lens, use the appropriate color for turn and brake light functions. When installed in a housing that has a matching colored lens, red and amber bulbs will appear brighter than white LED bulbs—even. What's the quickest way to show a red/green light indicator on a C# form? I originally thought about using radio buttons, but not sure how to set the color of the dot, only the foreground/background text. Then I thought about drawing a circle. Couldn't find a toolbox shape.
Why Is Catalina Not Showing In Updates
How To Stop Catalina Update
How To Update Catalina
How To Update To Os Catalina
The script content on this page is for navigation purposes only and does not alter the content in any way.
This manual provides instructions for servicing Oracle Database Appliance hardware. OracleDatabase Appliance comes in four versions:
Download cracked version MixMeister Fusion 7.7.0.1. As the coronavirus spreads, public and private companies as well as government entities are requiring employees to work from home, putting unforeseen strain on all manner of networking technologies and causing bandwidth and security. The most popular versions of MixMeister Fusion for Mac are 7.6 and 7.4. The file size of the latest setup package available for download is 157.1 MB. The actual developer of this software for Mac is MixMeister Technology. Create custom party mixes, burn CDs, or add special effects to MP3s with this line of DJ software for the novice and pro. Offers free trials and user community.
Oracle Database Appliance X5-2
You can record, play, and alter outsider instrument applications into this and offer your tunes utilizing email, Facebook, Cloud or AirDrop. Take after this on the best way to download GarageBand for Laptop/PC on Windows 8/10/8.1/7/xp/Vista 32 bit, 64 bit and Mac OS X Computer/Laptops. Presently download GarageBand for PC on Windows 8/10/8.1/7/xp/Vista 32 bit, 64 bit and Mac OS X Computer/Laptops to appreciate brilliant instrument and make your sound more than ever. Garageband 10. 1 free download. DOWNLOAD GARAGEBAND FOR PC ON WINDOWS/MAC LAPTOP FREERight away record the execution with the help of 32 tracks with GarageBand.
Oracle Database Appliance X4-2
Oracle Database Appliance X3-2
Oracle Database Appliance original version (also referred to as 'version 1' or 'V1')
The following sections in this chapter describe system status indicators and LEDs:
For information about system features and racking, refer to the Oracle DatabaseAppliance Owner's Guide. For information on cabling, Oracle ILOM initial setup, andappliance software setup, refer to the Oracle Database Appliance Getting StartedGuide.
Oracle Database Appliance X5-2 Status Indicators
This section describes the status indicators for Oracle Database Appliance X5-2.
Led Indicator For Mixmeister 3
Server Node Status Indicators
These topics describe Oracle Database Appliance X5-2 server node status indicators(LEDs).
Note:
The links below take you to topics outside of the Oracle DatabaseAppliance library to the Oracle Server X5-2 documentation library. Use your browser's Back button toreturn to the Oracle Database Appliance library.
Storage Shelf Status Indicators
Storage shelves are supported with Oracle Database Appliance X5-2. They include controls andindicators on the front panel, hard drives, SSD drives, power supplies, and SAS I/O modules.
Storage Shelf Front Panel and Drive Indicators
The following figure shows the controls and indicators on the storage shelf front panel anddrives.
Indicator/LED: ColorState Meaning
OK: green
On – The storage shelf is powered on and operating normally.
Off – The storage shelf is unplugged or turned off.
Off – Normal operation.
Steady on – A fault is present in the storage shelf.
Off – Normal operation.
Fast blink – This LED blinks to help locate the system. Operators can turn thisindicator on and off remotely using Oracle ILOM.
Pressing this button toggles the fast blink on or off.
Off – Normal operation.
Steady on – A fault is present in the disk drive.
On – The drive is installed and recognized by the system but there is no driveactivity.
Blink – The LED blinks randomly in response to data being written to or read from thedrive.
Off – The drive is powered off or the installed drive is not recognized by thesystem.
Tumblr media
Callout
Storage Shelf Back Panel Indicators
The following figure shows the controls and indicators on the storage shelf back panel anddrives.
Indicator/LED: ColorState Meaning
On – Indicates an AC power fault.
Off – Normal operation.
On – The power supply is operating normally.
Off – The power supply is unplugged or turned off.
4
On – The power supply is faulty.
Off – Normal operation.
OK – Lights green to indicate normal operation.
Service Required – Lights amber to indicate a fault with the I/O module (top module is0; bottom module is 1).
7
Host SAS port activity indicators (x4 per port): green
Callout
Oracle Database Appliance X3-2/X4-2 Status Indicators
This section describes the status indicators for Oracle Database Appliance X3-2 and OracleDatabase Appliance X4-2.
Server Node Status Indicators
Led Indicator For Mixmeister 7
These topics describe Oracle Database Appliance X3-2 and Oracle Database Appliance X4-2 servernode status indicators (LEDs).
Note:
The links in the following table take you to topics outside of the OracleDatabase Appliance library to the Sun Server X3-2 and Sun Server X4-2 documentation libraries. Useyour browser's Back button to return to the Oracle Database Appliance library.
Led Indicator For Mixmeister Free
ODA X4-2
Tumblr media
ODA X3-2
Storage Shelf Status Indicators
Storage shelves are supported with Oracle Database Appliance X3-2/X4-2. They include controlsand indicators on the front panel, hard drives, SSD drives, power supplies, and SAS I/Omodules.
Storage Shelf Front Panel and Drive Indicators
The following figure shows the controls and indicators on the storage shelf front panel anddrives.
Indicator/LED: ColorState Meaning
On – The storage shelf is powered on and operating normally.
Off – The storage shelf is unplugged or turned off.
Off – Normal operation.
Steady on – A fault is present in the storage shelf.
Off – Normal operation.
Fast blink – This LED blinks to help locate the system. Operators can turn thisindicator on and off remotely using Oracle ILOM.
Pressing this button toggles the fast blink on or off.
Off – Normal operation.
Steady on – A fault is present in the disk drive.
On – The drive is installed and recognized by the system but there is no driveactivity.
Blink – The LED blinks randomly in response to data being written to or read from thedrive.
Off – The drive is powered off or the installed drive is not recognized by thesystem.
Callout
Storage Shelf Back Panel Indicators
The following figure shows the controls and indicators on the storage shelf back panel anddrives.
Indicator/LED: ColorState Meaning
On – Indicates an AC power fault.
Off – Normal operation.
On – The power supply is operating normally.
Off – The power supply is unplugged or turned off.
4
On – The power supply is faulty.
Off – Normal operation.
OK – Lights green to indicate normal operation.
Service Required – Lights amber to indicate a fault with the I/O module (top module is0; bottom module is 1).
7
Host SAS port activity indicators (x4 per port): green
Callout
Oracle Database Appliance (Original Version) Status Indicators
This section describes the status indicators for the original version Oracle DatabaseAppliance.
Server Node Status Indicators
The following table lists and describes the general status indicators on the front and rearpanel of each Oracle Database Appliance (original version) server node.
Indicator/LED: ColorState Meaning
Off – Normal operation.
Fast blink – This LED blinks to help locate the system. Operators can turn thisindicator on and off remotely using Oracle ILOM.
Pressing this button toggles the fast blink on or off. It is also used to prove physicalpresence.
Indicator Test Mode – Push and hold the Locate button for 5 seconds to activate the pushto test feature, which causes all LEDs except disk activity and power supply LEDs to light for 15seconds.
Off – No power is supplied to the SP or it is not functional.
Amber – When lit indicates an SP fault.
Green – When steady on indicates that Oracle ILOM is fully functional. If blinking, POSTdiagnostics are running, Oracle ILOM is booting, or firmware is updating.
Note - The amber LED indicates the status of the watchdog timer. The watchdog timer runscontinuously, but it times out if it is not reset by Oracle ILOM. If it times out, the amber LED islit and the green LED is extinguished.
Off – Normal operation.
Fast Blink – The system is preparing a customer-replaceable unit (CRU) (disk drive, fanmodule, or power supply) for safe removal but it is not ready yet.
Steady on – The CRU can be safely removed.
Off – Normal operation.
Steady on – A fault is present in system or a subsystem within the chassis.
This LED indicates the operational state of the chassis. This LED can be in the followingstates:
Off – AC power is not present or the Oracle ILOM boot has not completed.
Standby blink – Standby power is on and Oracle ILOM can be accessed, but full chassispower is off. The LED blinks at a 10 percent duty cycle (0.1 second on, 2.9 seconds off), that is,the light is on for a very short period of time.
Slow blink – The startup sequence has been initiated on the host. The LED blinks at a 50percent duty cycle, which is noticeably longer than the STANDBY BLINK. This pattern should beginimmediately following powering on the system. This status indicates either 1) power-on self-test(POST) diagnostics running on system host or 2) the host is transitioning from the powered-on stateto the standby state on shutdown.
Steady on – The system is powered on and all host POST tests passed. The system is oneof the following states: 1) the system host is ready to boot, or 2) the system host is booting theoperating system (OS), or 3) the system host is running the OS.
Off – Normal operation.
Steady on – The system is experiencing an over-temperature warning condition.
Note - This is a warning indication, not a fatal over temperature. Failure to correct this can resultin the system over heating and shutting down.
Off – Normal operation.
Steady on – The system has detected a power supply fault, a fan fault, or a rear2.5-inch disk drive fault.
This fault condition is associated with chassis components located in the rear of the chassis.This fault might be caused by:
Power supply failure (AC fault, 12V/3.3Vaux fault, or power supply fan fault)
Rear fan failure
Rear 2.5-inch disk failure
Why Is Catalina Not Showing In Updates
Callout
Server Node Fan Indicators
Each fan module for Oracle Database Appliance (original version) has a single bi-colored LEDindicating both fan OK and fan fault conditions. The LED lights green to indicate that the fanmodule is properly plugged into the system and operating within the expected RPM range for a givenpower management setting. The LED lights amber to indicate a fan fault.
Note:
The LEDs on the fan modules are not lit amber on initial system power-on. The fan amber LEDonly lights if Oracle ILOM detects a failure that indicates a faulty fan module or a missing fanthat should be installed.Indicator/LED: Color
State Meaning
Steady on – The fan is functioning normally.
Off – Chassis 3.3V_Standby power is off or there is a fan fault.
Off – Normal operation.
Steady on – A fault has been detected with the fan.
Note - The front and rear panel Service Required LEDs are also lit if the system detects a fan modulefault.
Storage and Boot Drive Status Indicators
Each storage drive for Oracle Database Appliance (original version) includes three LEDs. Theyare the same on the front storage drives and the rear-mounted boot drives. See the followingtable.
Indicator/LED: ColorState Meaning
Off – Normal operation.
Fast blink – The system is preparing a disk drive for safe removal but it is not readyyet.
Steady on – The disk drive can be safely removed.
Off – Normal operation.
Steady on – A fault is present in the disk drive.
On – The drive is installed and recognized by the system but there is no driveactivity.
Blink – The LED blinks randomly in response to data being written to or read from thedrive.
Off – The drive is powered off or the installed drive is not recognized by thesystem.
Callout
Power Supply Status Indicators
There are three status LEDs on each power supply for Oracle Database Appliance (originalversion), as shown in the following table.
Indicator/LED: ColorState Meaning
OK: green
On – The power supply is operating normally.
Off – The power supply is unplugged or turned off.
On – The power supply is faulty. The front REAR PS LED and the front and rear panelService Required LEDs are also lit if the system detects a power supply fault.
Off – Normal operation.
On – The power supply is plugged in and AC power is available, regardless of systempower state.
Off – The power supply is unplugged or turned off.
Callout
Rear Server Node Status Indicators
Each server node in Oracle Database Appliance (original version) has four summary status LEDsthat are located on its back panel, as shown in the following table.
Tumblr media
Indicator/LED: ColorState Meaning
Off – Normal operation.
Fast blink – This LED blinks to help locate the system. Operators can turn thisindicator on and off remotely using Oracle ILOM.
Pressing this button toggles the fast blink on or off.
Indicator Test Mode – Push and hold the Locate button for 5 seconds to activate the pushto test feature, which causes all LEDs except disk activity and power supply LEDs to light for 15seconds.
Off – Normal operation.
Fast Blink – The system is preparing a customer-replaceable unit (CRU) (disk drive, fanmodule, or power supply) for safe removal but it is not ready yet.
Steady on – The CRU can be safely removed.
Off – Normal operation.
Steady on – A fault is present in system or a subsystem within the chassis.
This LED indicates the operational state of the chassis. This LED can be in the followingstates:
Off – AC power is not present or the Oracle ILOM boot has not completed.
Standby blink – Standby power is on and Oracle ILOM can be accessed, but full chassispower is off. The LED blinks at a 10 percent duty cycle (0.1 second on, 2.9 seconds off), that is,the light is on for a very short period of time.
Slow blink – The startup sequence has been initiated on the host. The LED blinks at a 50percent duty cycle, which is noticeably longer than the STANDBY BLINK. This pattern should beginimmediately following powering on the system. This status indicates either 1) power-on self-test(POST) diagnostics running on system host or 2) the host is transitioning from the powered-on stateto the standby state on shutdown.
Steady on – The system is powered on and all host POST tests passed. The system is oneof the following states: 1) the system host is ready to boot, or 2) the system host is booting theoperating system (OS), or 3) the system host is running the OS.
Callout
How To Stop Catalina Update
Server Node Internal LEDs
The following section describes the internal LEDs for Oracle Database Appliance (originalversion). Each server node contains the following internal LEDs:
Note:
A super capacitor (located on the motherboard) provides powerto light the server node fault LEDs for up to 15 minutes after the servernode is removed from a powered-on system chassis. After approximately 15 minutes,the capacitor discharges enough so that it cannot light the fault LEDs.
Fault Remind Power Good LED.
This green LED lightseach time the Fault Remind button is pressed, if the capacitor has enoughof a charge to light the fault LEDs. This LED is located next to the FaultRemind button.
For the location of Fault Remind button and the Fault Remind Power GoodLED, see Remove Faulty DIMMs.
Memory DIMM Fault LEDs
Each DIMM slot has an adjacentDIMM fault LED. If a DIMM fails, the adjacent LED lights when the Fault Remindbutton is pressed.
For the location of Fault Remind button and the DIMM fault LEDs, see Remove Faulty DIMMs.
CPU Fault LEDs
Both CPUs have an associated CPUfault LED. If a CPU fails, the associated LED lights when the Fault Remindbutton is pressed.
For the location of CPU fault LEDs, see Remove Processor (CPU).
Ethernet Port LEDs
Each server node has two hostEthernet ports (NET0 and NET1) and an SP network management port (NET MGT).Each of these has two LEDs that indicate link activity and port speed. See Ethernet Port Indicators.
How To Update Catalina
Ethernet Port Indicators
Each server node in Oracle Database Appliance (original version) has two host Ethernet ports(NET0 and NET1) and an SP network management port (NET MGT). Each of these has two LEDs thatindicate link activity and port speed.
How To Update To Os Catalina
Lights to indicate link activity.
Amber – Link established at next fastest speed or slower speeds.
808 Drum Kit Download Garageband»
0 notes